A Potentiometric Sensor for Determination of Doxycycline Hydrochloride in Pharmaceutical Preparation and Biological Fluids
- 作者: Ali T.A.1, Mohamed G.G.2, El-Sonbati A.Z.2, Diab M.A.2, Elkfass A.M.2
- 
							隶属关系: 
							- Egyptian Petroleum Research Institute (EPRI)
- Chemistry Department, Faculty of Science
 
- 期: 卷 54, 编号 12 (2018)
- 页面: 1081-1095
- 栏目: Article
- URL: https://journals.rcsi.science/1023-1935/article/view/190105
- DOI: https://doi.org/10.1134/S1023193518120029
- ID: 190105
如何引用文章
详细
This article focused on the construction and characteristics of novelty and sensitivity of modified carbon paste electrodes for determination of doxycycline hydrochloride (DC.HCl) in urine, serum and pharmaceutical preparations. It was based on the incorporation of α-cyclodextrine (α-CD) and multi-walled carbon nanotube (MWCNT) ionophores which improved the characteristics of the electrodes with tricresylphosphate (TCP) (electrode I) and o-nitrophenyloctylether (o-NPOE) (electrode II) as plasticizers, respectively. The constructed electrodes, at optimum paste composition, exhibited good Nernstian response for determination of doxycycline hydrochloride over a linear concentration range from 1.0 × 10–7 to 1.0 × 10–2 and 1.22 × 10–7 to 1.0 × 10–2 mol L–1 with detection limit of 1.0 × 10–7 and 1.22 ×10–7 mol L–1 and with slope values of (58.7 ± 0.2) mV decade–1 and (58.0 ± 0.6) mV decade–1, for modified carbon paste electrodes (MCPEs; electrodes I and II), respectively. The results showed fast dynamic response time (about 6–7 s) and long lifetime in the range from 4 to 5 months where the response of the electrodes was not affected by pH variation within the range from 2 to 8 and 2 to 7.5 for electrodes I and II, respectively. Electrodes I and II showed high selectivity for doxycycline hydrochloride with respect to a large number of interfering species including foreign inorganic, organic species, excipients and the fillers added to the pharmaceutical preparation. The constructed electrodes were successfully applied for determination of DC.HCl in pure form, its pharmaceutical preparations and biological fluids (urine and serum) using standard addition, calibration curves and potentiometric titration methods. The results obtained using these potentiometric electrodes were comparable with those obtained using official method. The results were satisfactory with excellent percentage recovery comparable or better than those obtained by other routine methods.
作者简介
T. Ali
Egyptian Petroleum Research Institute (EPRI)
							编辑信件的主要联系方式.
							Email: dr_tamerawad@yahoo.com
				                					                																			                												                	埃及, 							Cairo, 11727						
G. Mohamed
Chemistry Department, Faculty of Science
														Email: dr_tamerawad@yahoo.com
				                					                																			                												                	埃及, 							Giza, 12613						
A. El-Sonbati
Chemistry Department, Faculty of Science
														Email: dr_tamerawad@yahoo.com
				                					                																			                												                	埃及, 							Damietta						
M. Diab
Chemistry Department, Faculty of Science
														Email: dr_tamerawad@yahoo.com
				                					                																			                												                	埃及, 							Damietta						
A. Elkfass
Chemistry Department, Faculty of Science
														Email: dr_tamerawad@yahoo.com
				                					                																			                												                	埃及, 							Giza, 12613						
补充文件
 
				
			 
						 
						 
					 
						 
						 
				 
  
  
  
  
  电邮这篇文章
			电邮这篇文章  开放存取
		                                开放存取 ##reader.subscriptionAccessGranted##
						##reader.subscriptionAccessGranted## 订阅存取
		                                		                                        订阅存取
		                                					