New structural designs of integrating devices by means of which the precision of integration of electrical signals in the range of ultra-low frequencies 2·10–3–3 Hz may be increased are presented. Practical designs of second-order integrators and their transfer functions are considered. Results of calculations that confirm an increase in the precision of integration of signals by a second-order integrator by comparison with a first-order integrator as a function of the frequency of the device are presented.