A Method of Determining the Level of Dielectric Liquids from the Parameters of a Model of a Capacitance Fuel Level Sensor
- Authors: Balakin S.V.1,2, Serbinov D.L.1
-
Affiliations:
- Korolev Rocket and Space Corporation Energiya
- Moscow Institute of Electronics and Mathematics, National Research University Higher School of Economics (MIEM HSE)
- Issue: Vol 60, No 10 (2018)
- Pages: 998-1002
- Section: Article
- URL: https://journals.rcsi.science/0543-1972/article/view/246303
- DOI: https://doi.org/10.1007/s11018-018-1307-7
- ID: 246303
Cite item
Abstract
A method of determining the level of dielectric liquids from the parameters of a model of a capacitance level sensor and a model of a communication line is considered. The proposed method may be used to eliminate the influence of faults in the communication line on the results of a determination of the fueling level of a tank and increase the reliability with which this level is determined. Requirements imposed on a capacitance level sensor and the communication line are described. Analytic expressions for determining the parameters of a level sensor and the communication line as well as the components of the error in the determination of the fueling level are presented.
About the authors
S. V. Balakin
Korolev Rocket and Space Corporation Energiya; Moscow Institute of Electronics and Mathematics, National Research University Higher School of Economics (MIEM HSE)
Author for correspondence.
Email: post2@rsce.ru
Russian Federation, Korolev, Moscow District; Moscow
D. L. Serbinov
Korolev Rocket and Space Corporation Energiya
Email: post2@rsce.ru
Russian Federation, Korolev, Moscow District
Supplementary files