Features of the Determination of the Complex Transfer Coefficients of a Frequency Converter by Methods of Combined Measurements
- Authors: Frolov D.R.1, Babenko A.A.1, Biryuk A.E.1, Kozhevnikov V.V.1, Svidlov A.A.1
-
Affiliations:
- Kuban State University
- Issue: Vol 60, No 3 (2017)
- Pages: 274-278
- Section: Radio Measurements
- URL: https://journals.rcsi.science/0543-1972/article/view/246110
- DOI: https://doi.org/10.1007/s11018-017-1185-4
- ID: 246110
Cite item
Abstract
We consider causes that limit the accuracy of the measurements of complex transfer coefficients (CTCs) of a frequency converter by methods based on various combinations of parallel and series connections of the indicated converters. It is impossible to carry out such measurements without using a reciprocal frequency converter. It was established that the limiting accuracy of the given measurement methods was determined by the degree of reciprocity of at least one of the frequency converters.