Thermal Resistance of the Wall Layer of Molten Glass in the High-Temperature Corrosion Zone of the Refractory Walls of the Melting Tank of Glassmaking Furnaces


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

Ascientifically substantiated applied method of performing engineering calculations of the thermal resistance of the wall layer has been developed. This procedure makes it possible to take account of additional factors—temperature of the melt and composition of the molten glass in the melting tank — and make more accurate predictions of the temperature in corrosion-active zones of the refractory barriers of glassmaking furnaces.

About the authors

B. A. Semenov

Yu. A. Gagarin Saratov State Technical University

Email: nikita-alecseevich@yandex.ru
Russian Federation, Saratov

N. A. Ozerov

Yu. A. Gagarin Saratov State Technical University

Author for correspondence.
Email: nikita-alecseevich@yandex.ru
Russian Federation, Saratov

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2016 Springer Science+Business Media New York