An Automated Flow Traversing Measurement System in the Last Stages of Large-Capacity Steam Turbines
- 作者: Moskalenko A.V.1, Aleksandrov A.V.1, Nekrasov A.L.1, Ivanov S.A.1, Dolganov A.G.1, Kravtsova N.V.1, Gostev O.D.2, Morkinskii D.O.2, Laskin A.S.3
-
隶属关系:
- PJSC Power Machines Leningradsky Metallichesky Zavod
- LLP PromAvtomatika
- Peter the Great St. Petersburg Polytechnic University
- 期: 卷 66, 编号 1 (2019)
- 页面: 27-35
- 栏目: Steam Turbine, Gas Turbine, Combined-Cycle Power Plants, and Their Auxiliary Equipment
- URL: https://journals.rcsi.science/0040-6015/article/view/173181
- DOI: https://doi.org/10.1134/S0040601519010051
- ID: 173181
如何引用文章
详细
The article presents the results from putting a new automated flow traversing measurement system (AFTMS) in an experimental turbine intended for testing steam paths of the low-pressure cylinders (LPC) of large-capacity steam turbines into use. Modern computerized facilities have been used in developing the system. Such an approach has been implemented for the first time in the full-scale test bench available at PJSC Power Machines in carrying out experimental investigations of an LPC double stage compartment (on a 1 : 1 scale) equipped with a new, ultimately long last stage blade (LSB) developed for a steam turbine plant for ultrasupercritical steam conditions. The investigations were aimed at confirming the effectiveness of the developed system in measuring the flow parameters in the last LPC stage. The necessity of making a shift from nonautomated and semiautomatic systems to the use of automated measurement systems is substantiated. The article describes a system that makes it possible, with automated setting of the gas dynamic probe head position on the traversing line, to determine the steam flow direction; to measure the stagnation pressure, static pressure, and stagnation temperature; and to record the measures indicators with exactly assigned time tags. The results from measurements of flow parameters upstream of the last LPC stage in a partial load mode are given. A comparison between the experimental and calculated flow parameter distribution data over the stage radius in the control section is shown.
作者简介
A. Moskalenko
PJSC Power Machines Leningradsky Metallichesky Zavod
编辑信件的主要联系方式.
Email: moskalenko_av@power-m.ru
俄罗斯联邦, St. Petersburg, 195009
A. Aleksandrov
PJSC Power Machines Leningradsky Metallichesky Zavod
Email: moskalenko_av@power-m.ru
俄罗斯联邦, St. Petersburg, 195009
A. Nekrasov
PJSC Power Machines Leningradsky Metallichesky Zavod
Email: moskalenko_av@power-m.ru
俄罗斯联邦, St. Petersburg, 195009
S. Ivanov
PJSC Power Machines Leningradsky Metallichesky Zavod
Email: moskalenko_av@power-m.ru
俄罗斯联邦, St. Petersburg, 195009
A. Dolganov
PJSC Power Machines Leningradsky Metallichesky Zavod
Email: moskalenko_av@power-m.ru
俄罗斯联邦, St. Petersburg, 195009
N. Kravtsova
PJSC Power Machines Leningradsky Metallichesky Zavod
Email: moskalenko_av@power-m.ru
俄罗斯联邦, St. Petersburg, 195009
O. Gostev
LLP PromAvtomatika
Email: moskalenko_av@power-m.ru
俄罗斯联邦, St. Petersburg, 194044
D. Morkinskii
LLP PromAvtomatika
Email: moskalenko_av@power-m.ru
俄罗斯联邦, St. Petersburg, 194044
A. Laskin
Peter the Great St. Petersburg Polytechnic University
Email: moskalenko_av@power-m.ru
俄罗斯联邦, St. Petersburg, 195251
补充文件