On the Impact of Cleaning Widened Sections of Boreholes on the Bearing Capacity of Bored Situ-Cast Piles
- Авторлар: Dzagov A.M.1, Kitaikin V.A.1, Chernov R.I.1
-
Мекемелер:
- N. M. Gersevanov Research Institute of Bases and Underground Structures
- Шығарылым: Том 53, № 4 (2016)
- Беттер: 274-281
- Бөлім: Technology and Work Production
- URL: https://journals.rcsi.science/0038-0741/article/view/244047
- DOI: https://doi.org/10.1007/s11204-016-9398-0
- ID: 244047
Дәйексөз келтіру
Аннотация
A process aspect of installing bored situ-cast piles-the cleaning of widened borehole sections and its impact on the pile bearing capacity in slightly moist clay soil-is examined. Results are presented of field static tests on bored situ-cast piles fabricated using both the manufacturing process and installed in boreholes after they have been completely cleaned of drilling waste. A significant divergence is established between design and experimental values of soil resistance R under the pile, which suggests a need to update SP 24.1330.2011.
Авторлар туралы
A. Dzagov
N. M. Gersevanov Research Institute of Bases and Underground Structures
Email: smfe@mail.ru
Ресей, Moscow
V. Kitaikin
N. M. Gersevanov Research Institute of Bases and Underground Structures
Email: smfe@mail.ru
Ресей, Moscow
R. Chernov
N. M. Gersevanov Research Institute of Bases and Underground Structures
Email: smfe@mail.ru
Ресей, Moscow
Қосымша файлдар