详细
The systematic error in measuring the duration of flashes by the correlation counter that was developed by the authors earlier on the basis of a digital oscilloscope and a computer has been reduced by 1–2 ns by mathematical processing of input pulses and by correction of their recording times. The variance in the measured duration and delay of flashes does not change when the correction is applied. The technique has been tested on model flashes, and the time of sonoluminescence flashes has been clarified. The counter can be used to measure other fast events, e.g., in nuclear physics.
作者简介
M. Kazachek
Pacific Oceanological Institute
编辑信件的主要联系方式.
Email: tanya@poi.dvo.ru
690041, Vladivostok, Russia
参考
- Казачек М.В., Гордейчук Т.В. // ПТЭ. 2019. № 1. С. 28. https://doi.org/10.1134/S0032816219010117
- Казачек М.В. Свидетельство о государственной регистрации программы для ЭВМ № 2018619059 // Опубл. 27.07. 2018.
- Walton A.J., Reynolds G.T. // Advances in Physics. 1984. V. 33. № 6. P. 595. https://doi.org/10.1080/00018738400101711
- Гордейчук Т.В., Казачек М.В. // Оптика и спектроскопия. 2020. Т. 128. № 10. С. 1492. https://doi.org/10.21883/OS.2020.10.50020.169-20
- Gompf B., Gunter R., Nick G., Pecha R., Eisenmenger W. // Physical Review Letters. 1997. V. 79. № 7. P. 1405.
- Aavikko R. Thesis …Doctor from the Helsinki University of Technology. Speciality: Science in Technology. Helsinki, Finland. 2006. P. 17.
- Ko I., Kwak H.-Y. // Journal of Physical Society of Japan. 2010. V. 79. № 12. P. 124401. https://doi.org/10.1143/JPSJ.79.124401
补充文件