Obzor metodov snizheniya stepeni obledeneniya i ottayki ispariteley teplovykh nasosov
- Authors: Garanov S.A.1, Zabolotnyy D.Y.1, Protopopov K.V.2
-
Affiliations:
- 105005, Москва, ул. 2-я Бауманская, д. 5
- ООО «СКВ»
- Issue: Vol 105, No 12 (2016)
- Pages: 28-35
- Section: Articles
- URL: https://journals.rcsi.science/0023-124X/article/view/99156
- DOI: https://doi.org/10.17816/RF99156
- ID: 99156
Cite item
Abstract
Keywords
Full Text
##article.viewOnOriginalSite##About the authors
Sergey Aleksandrovich Garanov
105005, Москва, ул. 2-я Бауманская, д. 5
Email: garanovsergey@yandex.ru
Канд. техн. наук
Denis Yur'evich Zabolotnyy
105005, Москва, ул. 2-я Бауманская, д. 5
Email: zabdenis1996@gmail.com
Kuz'ma Valer'evich Protopopov
ООО «СКВ»
Email: kuzma.polonsky@yandex.ru
Москва, Локомотивный проезд, д. 19
References
- Byrne P., Miriel J., Lenat Y. Experimental study of an airsource heat pump for simultaneous heating and cooling - Part 1: Basic concepts and performance verification// Applied Energy, Elsevier, 2011, 88 (5), 1841-1847.
- Byrne P., Miriel J., Lenat Y. Experimental study of an airsource heat pump for simultaneous heating and cooling - Part 2: Dynamic behaviour and twophase thermosiphon defrosting technique// Applied Energy, 2011, 88, 3072-3078.
- Byun J.S., Leeb J.H., Jeon C.D. Frost retardation of an airsource heat pump by the hot gas bypass method// International Journal of Refrigeration, 2008, 31, 328-334.
- Cho H.Y., Kima Y.C., Jang I.K. Performance of a showcase refrigeration system with multievaporator during on-off cycling and hotgas bypass defrost// Energy, 2005, 30, 1915-1930.
- Dong Jiankai, Jiang Yiqiang, Yao Yang, Zhang Xuedan. Operating performance of novel reversecycle defrosting method based on thermal energy storage for air source heat pump// J. Cent. South Univ. Technol. 2011, 18, 2163-2169.
- Dong Jiankai, Jiang Yiqiang, Deng Shiming, Yao Yang and Qu Minglu. Improving reverse cycle defrosting performance of air source heat pumps using thermal storagebased refrigerant subcooling energy // Building Services Engineering Research and Technology. 2012, 33, 223-236.
- Dopazo J. Alberto, FernandezSeara Jose, Uhı´a Francisco J. Modelling and experimental validation of the hotgas defrost process of an aircooled evaporator// International journal of refrigeration. 2010, 33, 829 - 839.
- Guangcai Gong, Jinchen Tang, DongyanLv, Hongjin Wang. Research on frost formation in air source heat pump at coldmoist conditions in centralsouth China// Applied Energy, 2013, 102, 571-581.
- Haihui Tan, Tangfei Tao, Guanghua Xu, Sicong Zhang, Dingyuan Wanga, Xiangui Luo. Experimental study on defrosting mechanism of intermittent ultrasonic resonance for a finnedtube evaporator [J]. Experimental Thermal and Fluid Science, 2014, 52, 308-317.
- Hewitt N., Huang M.J. Defrost cycle performance for a circular shape evaporator air source heat pump// International Journal of Refrigeration, 2008, 31, 444-452.
- Huang Dong, Li Quanxu, Yuan X L. Comparison between hotgas bypass defrosting and reversecycle defrosting methods on an airtowater heat pump// Applied Energy, 2009, 86, 1697-1703.
- Jhee S., Lee K.S., Kim W.S. Effect of surface treatments on the frosting/defrosting behavior of a fintube heat exchanger// International Journal of Refrigeration, 2002, 25, 1047-1053.
- Joppolo Cesare Maria, Molinaroli Luca, De Antonellis Stefano, Merlo Umberto. Experimental analysis of frost formation with the presence of an electric field on fin and tube evaporator // International journal of refrigeration. 2012, 35, 468-474.
- Kondepudi S.N., O’Neal D.L. The effects of frost growth on extended surface heat exchanger performance. A review// ASHRAE Trans, 1987, 93, 258-274.
- Kyoungmin Kim, MinHwan Kim, Dong Rip Kim, KwanSoo Lee. Thermal performance of microchannel heat exchangers according to the design parameters under the frosting conditions// International Journal of Heat and Mass Transfer, 2014, 71, 626-632.
- Seker D., Karatas H. Frost formation on finandtube heat exchangers. Part II - experimental investigation of frost formation on finandtube heat exchangers// Refrigeration 2004, 27, 375-377.
- Wang S.W., Liu Z.Y. A new method for preventing HP from frosting// Renewable Energy, 2005, 30, 753-761.
- Yan W.M., Li H.Y. Performance of finned tube heat exchangers operating under frosting conditions// Heat Mass Trans, 2003, 46, 871-877.
- Yiqiang Jiang, Huiying Fu, Yang Yao, Ling Yan, Qiang Gao. Experimental study on concentration change of spray solution used for a novel nonfrosting air source heat pump system// Energy and Buildings, 2014, 68, 707-712.
Supplementary files