Approach to low-frequency magnetic field measurements using permalloy-based magnetoplasmonic crystal

Cover Page

Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

This paper demonstrates the use of a one-dimensional magnetoplasmonic crystal based on Ni80Fe20 permalloy as a sensitive probe of a magneto-optical sensor for low-frequency AC field measurements. The sensitivity of the sensor reaches 30 mOe when operating in the frequency range from 0.1 to 100 Hz. In the course of the work, an assessment was made of the applicability of the developed sensor for measuring magnetic fields of biological objects that were subjected to electrical stimulation.

About the authors

V. K. Belyaev

Immanuel Kant Baltic Federal University

Email: vbelyaev@kantiana.ru
Alexander Nevsky St., 14, Kaliningrad, 236041 Russia

S. E. Pshenichnikov

Immanuel Kant Baltic Federal University

Email: vbelyaev@kantiana.ru
Alexander Nevsky St., 14, Kaliningrad, 236041 Russia

A. E. Andryukov

Immanuel Kant Baltic Federal University

Email: vbelyaev@kantiana.ru
Alexander Nevsky St., 14, Kaliningrad, 236041 Russia

D. V. Murzin

Immanuel Kant Baltic Federal University

Email: vbelyaev@kantiana.ru
Alexander Nevsky St., 14, Kaliningrad, 236041 Russia

L. V. Panina

Immanuel Kant Baltic Federal University; National Research Technological University MISiS

Email: vbelyaev@kantiana.ru
Alexander Nevsky St., 14, Kaliningrad, 236041 Russia; Leninsky Ave., 4, bld. 1, Moscow, 119049 Russia

E. V. Levada

Immanuel Kant Baltic Federal University

Email: vbelyaev@kantiana.ru
Alexander Nevsky St., 14, Kaliningrad, 236041 Russia

V. V. Rodionova

Immanuel Kant Baltic Federal University

Author for correspondence.
Email: vbelyaev@kantiana.ru
Alexander Nevsky St., 14, Kaliningrad, 236041 Russia

References

  1. Grosz A., Haji-Sheikh M.J., Mukhopadhyay S.C. High sensitivity magnetometers. Switzerland: Springer, 2017. C. 576.
  2. Murzin D., Mapps D.J., Levada K. Belyaev V., Omelyanchik A., Panina L., Rodionova V. Ultrasensitive magnetic field sensors for biomedical applications // Sensors. 2020. V. 20. No. 6. P. 1569.
  3. Fabricant A., Novikova I., Bison G. How to build a magnetometer with thermal atomic vapor: a tutorial // New J. Phys. 2023. V. 25. No. 2. P. 025001.
  4. Aslam N., Zhou H., Urbach E.K., Turner M.J., Walsworth R.L., Lukin M.D., Park H. Quantum sensors for biomedical applications // Nature Rev. Phys. 2023. V. 5. No. 3. P. 157–169.
  5. Rizal C., Manera M.G., Ignatyeva D.O., Mejía-Salazar J.R., Rella R., Belotelov V.I., Pineider F., Maccaferri N. Magnetophotonics for sensing and magnetometry toward industrial applications // J. Appl. Phys. 2021. V. 130. No. 23.
  6. Rogachev A.E., Vetoshko P.M., Gusev N.A., Kozhaev M.A., Prokopov A.R., Popov V.V., Dodonov D.V., Shumilov A.G., Shaposhnikov A.N., Berzhansky V.N., Zvezdin A.K. Vector magneto-optical sensor based on transparent magnetic films with cubic crystallographic symmetry // Appl. Phys. Letters. 2016. V. 109. No. 16.
  7. Dorosinskiy L., Sievers S. Magneto-Optical Indicator Films: Fabrication, Principles of Operation, Calibration, and Applications // Sensors. 2023. V. 23. No. 8. P. 4048.
  8. Belotelov V.I., Akimov I.A., Pohl M., Kotov V.A., Kasture S., Vengurlekar A.S., Gopal A.V., Yakovlev D.R., Zvezdin A.K., Bayer M. Enhanced magneto-optical effects in magnetoplasmonic crystals // Nature nanotechn. 2016. V. 6. No. 6. P. 370–376.
  9. Kiryanov M.A., Frolov A.Y., Novikov I.A., Kipp P.A., Nurgalieva P.K., Popov V.V., Ezhov A.A., Dolgova T.V., Fedyanin A.A. Surface profile-tailored magneto-optics in magnetoplasmonic crystals // APL Photonics. 2022. V. 7. No. 2.
  10. Murzin D.V., Belyaev V.K., Gritsenko K.A., Rodionova V.V. Effect of Filling Factor on the Coefficient of Reflection and Transversal Kerr Effect of 2D Permalloy-Based Magnetoplasmonic Crystals // Bulletin of the Russian Academy of Sciences: Physics. 2024. V. 88. No. 4. P. 591–596.
  11. Zayats A.V., Smolyaninov I.I. Near-field photonics: surface plasmon polaritons and localized surface plasmons // J. Optics A: Pure and App. Optics. 2003. V. 5. No. 4. P. S16.
  12. Belyaev V.K., Rodionova V.V., Grunin A.A., Inoue M., Fedyanin A.A. Magnetic field sensor based on magnetoplasmonic crystal // Sci. Rep. 2020. V. 10. No. 1. P. 7133.
  13. Murzin D.V., Belyaev V.K., Mamian K.A., Groß F., Gräfe J., Frolov A.Y., Fedyanin A.A., Rodionova V.V. Ni80Fe20 Thickness Optimization of Magnetoplasmonic Crystals for Magnetic Field Sensing // Sensors and Actuators A: Physical. 2024. V. 376. P. 115552.
  14. Knyazev G.A., Kapralov P.O., Gusev N.A., Kalish A.N., Vetoshko P.M., Dagesyan S.A., Shaposhnikov A.N., Prokopov A.R., Berzhansky V.N., Zvezdin A.K., Belotelov V.I. Magnetoplasmonic crystals for highly sensitive magnetometry // ACS Photonics. 2018. V. 5. No. 12. P. 4951–4959.
  15. Пахотин В.А., Бессонов В.А., Молостова С.В., Власова К.В. Теоретические основы оптимальной обработки сигналов: курс лекций для радиофизических специальностей. Калининград: РГУ им. И. Канта, 2008. C. 189.
  16. Аббасова К.Р., Богачева П.О., Васильев А.Н. и др. Руководство к практическим занятиям по физиологии человека и животных / учебно-методическое пособие для студентов 3-го курса биологического факультета МГУ имени М. В. Ломоносова, обучающихся по программе бакалавриата. Москва: Товарищество науч. изд. КМК. C. 277.
  17. Zhu K., Kiourti A. A review of magnetic field emissions from the human body: Sources, sensors, and uses // IEEE Open Journal of Antennas and Propagation. 2022. V. 3. P. 732–744.
  18. Roth B.J. Biomagnetism: the first sixty years // Sensors. 2023. V. 23. No. 9. P. 4218.

Supplementary files

Supplementary Files
Action
1. JATS XML


Согласие на обработку персональных данных

 

Используя сайт https://journals.rcsi.science, я (далее – «Пользователь» или «Субъект персональных данных») даю согласие на обработку персональных данных на этом сайте (текст Согласия) и на обработку персональных данных с помощью сервиса «Яндекс.Метрика» (текст Согласия).