Role arteriovenous fistula in femoral-tibial bypass surgery

Abstract

The article provides an overview of world literature data on existing techniques to improve the results of distal reconstructions by applying arteriovenous fistulas in the formation of the distal anastomosis in patients with obliterating diseases of the lower extremities. The data on the benefits of worldwide research of a method depending on the type, shape and location of venous cuffs or patches. Examined the immediate and long-term outcomes with the use of these techniques, data analysis, comparative application autovenous grafts, shunts combined with the use of arteriovenous fistulas in the formation of distal anastomosis and PTFE prostheses in position below the gap of the knee.

References

  1. Бальцер К. Оправдано ли применение аллопластического материала при берцовых реконструкциях? / К. Бальцер, И.М. Гудз, С.Н. Генык // Ангиология и сосудистая хирургия. - 1999. -Т. 5, №1. - С. 89-94.
  2. Гавриленко А.В. Влияние факторов риска на результаты реконструктивных операций в бедренно-подколенной зоне / А.В. Гавриленко, А.Н. Косенков, С.И. Скрылев // Анналы хирургии. - 1997. -№5. - С. 52-56.
  3. Дистальное шунтирование при критической ишемии нижних конечностей у больных моложе и старше 80 лет / И.П. Дуданов [и др.] // Вестн. хирургии им. Грекова. - 1997. -№ 2. - С. 47-50.
  4. Золкин В.Н. Способы, позволяющие улучшить отдаленные результаты хирургического лечения больных с критической ишемией нижних конечностей / В.Н. Золкин, А.В. Матюшкин, A.А. Лобачев // Ангиология и сосудистая хирургия. - 2010. - Т. 16, №4 (Прил.). - С. 136-137.
  5. Каримов З.З. Хирургическое лечение окклюзий бедренно-подколенно-берцового сегмента при критической ишемии / З.З. Каримов // Ангиология и сосудистая хирургия. - 2001. - №2. - С. 88-92.
  6. Клиническая ангиология: руководство / под ред. А.В. Покровского. - М.: Медицина, 2004.
  7. Сосудистая хирургия по Хаймовичу: pуководство / под ред. Э. Ашер. - М.: Бином, 2010.
  8. Эббот У.М. В каких случаях следует применять синтетические протезы и можно ли улучшить проходимость с помощью венозных манжеток или других вспомогательных средств? / У.М. Эббот // Ангиология и Сосудистая хирургия. - 2000. - №2. - С. 75-80.
  9. Adjunctive techniques to improve patency of distal prosthetic bypass grafts: Polytetrafluoroethylene with remote arteriovenous fistulae versus vein cuffs / Paul B. Kreienberg [et al.] // Journal of Vascular Surgery. - 2000. - Vol. 31, Is.4. -P. 696-701.
  10. Adjuvant arteriovenous fistula as means of rescue for infrapopliteal venous by pass with poor runoff / K. Laurila [et al.] // J Vasc Surg. - 2006. - Vol. 44. -Р. 985-991.
  11. Batson R.C. Linton patch angioplasty, an adjunct to distal bypass with polytetrafluoroethylene grafts / R.C. Batson, S.S. Vikrom, C.C. Craighead // Ann Surg. -1984. - №6. - Р. 684-693.
  12. Blood flow in distal end-to-side anastomoses with PTFE and a venous patch: results of an in vitro flow visualisation study / N. Noori [et al.] // Eur J Vasc Endovasc Surg. - 1999. - Vol. 18. - Р. 191-200.
  13. Complementary distal arteriovenous fistula and deep vein interposition: a five year experience with a technique to improve infrapopliteal prosthetic bypass patency / E. Ascer [et al.] // J Vasc Surg. -1996. - Vol. 24. - Р. 134-143.
  14. Distal vein patch with an arteriovenous fistula: A viable option for the patient without autogenous conduit and severe distal occlusive disease / Richard F. Neville [et al.] // J. of Vasc. Surgery. - 2009. - Vol. 50, № 1. - P. 83-88.
  15. Haemodynamics of the interposition vein cuff Issue / J.D. Beard [et al.] // Br J Surg. -1986. - Vol. 73, №10. - Р. 823-825.
  16. Improved technique for polytetrafluoroethylene bypass grafting: long-term results using anastomotic vein patches / R.S. Taylor [et al.] // Br J Surg. - 1992. -Vol. 79. - Р. 348-354.
  17. In situ versus reversed femoropopliteal vein grafts: long-term follow-up of a prospective, randomized trial / A.P. Moody [et al.] // Br. J. Surg. - 1992. - Vol. 79. -Р. 750-752.
  18. Interposition vein cuff anastomosis alters wall shear stress distribution in the recipient artery / T.V. How [et al.] // J Vasc Surg. - 2000. - Vol. 31. - Р. 1008-1017.
  19. Interposition vein cuff for anastomosis of prostheses to small artery / J.H. Miller [et al.] // Aust NZ J Surg. - 1984. - Vol. 54. - P. 283-285.
  20. Neville R.F. Tibial bypass for limb salvage using polytetrafluoroethylene and a distal vein patch / R.F. Neville, B. Tempesta, A.N. Sidawy // J Vasc Surg. - 2001. - Vol. 33. - Р. 266-272.
  21. Patency and limb salvage after distal prosthetic bypass associated with vein cuff and arteriovenous fistula / E. Ducasse [et al.] // Euro J Vasc Endovasc Surg. - 2004. - Vol. 27. - Р. 417-422.
  22. Richard D.M. The effect of a venous anastomosis Tyrell vein collar on the primary patency of arteriovenous grafts in patients undergoing hemodialysis / D.M. Richard, Jeffrey Martinez, Paul J. Gagne // J Vasc Surg. - 2000. - Vol. 32, №6. - Р. 1149-1154.
  23. Rutherford Vascular Surgery: in 2 vol. / ed.: B. Robert. - 6th ed. - Philadelphia: Saunders, 2005.
  24. Siegman F.A. The use of the venous cuff for graft anastomosis / F.A. Siegman // Surg Gynecol Obstet. - 1979. - Vol. 148. - Р. 930.
  25. Stonebridge P. Randomized trial comparing infrainguinal polytetrafluoroethylene bypass grafting with and without interposition vein cuff at the distal anastomosis / P. Stonebridge, R. Prescott, C. Ruckley // J Vasc Surg - 1997. - Vol. 26. - Р. 543-550.
  26. Suggs W.D. Vein cuff interposition prevents juxtaanastomotic hyperplasia / W.D. Suggs, H.F. Enrique, R.G. DePalma // Ann Surg -1988. - Vol. 207. - Р. 717-723.
  27. The protective effect of vein cuffed anastomoses is not mechanical in origin / J.J. Noberto [et al.] // J Vasc Surg. - 1995. -Vol. 21. - Р. 558-566.

Supplementary files

Supplementary Files
Action
1. JATS XML

Copyright (c) 2014 Pokrovsky A.V., Yahontov D.I.

Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 International License.
 


Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».