ASSESSMENT of bIoresorbable Screws and bone tissue in long-term period after the anterior cruciate ligament reconstruction

Cover Page

Cite item

Full Text

Abstract

The use of bioresorbable materials in the anterior cruciate ligament reconstruction is a promising direction. Thus today there is no single point of view on the long-term results of using absorbable interference screws. The article presents an analysis of the results of surgical treatment of 30 patients with use of bioresorbable materials, operated on for rupture of the anterior cruciate ligament (ACL) in the department of traumatology and orthopedics from 2010 to 2016 in the Federal Scientific Clinical Center FMBA of Russia. The aim of our study was to evaluate in vivo transformation of bioresorbable screws and bone assimilation into the tibial canal in long-term period after surgery, as well as the effect of the polymeric material and bone on these processes.

About the authors

E A Zvezdkina

Федеральный научно-клинический центр специализированных видов медицинской помощи и медицинских технологий ФМБА России

Email: zvezdkina@yandex.ru
врач-рентгенолог, ассистент кафедры рентгенологии и ультразвуковой диагностики Института повышения квалификации ФМБА России,к.м.н.

V N Lesnyak

Федеральный научно-клинический центр специализированных видов медицинской помощи и медицинских технологий ФМБА России

Email: lesnyak_kb83@mail.ru
зав. рентгенологическим отделением ФНКЦ ФМБА России, заведующий кафедрой рентгенологии и ультразвуковой диагностики Института повышения квалификации ФМБА России, Заслуженный врач России, к.м.н.

A A Akhpashev

Российский университет дружбы народов

Email: akhpashev@yandex.ru
врач травматолог-ортопед, кандидат медицинских наук, доцент кафедры травматологии, ортопедии и артрологии факультета повышения квалификации медицинских работников Российского университета дружбы народов

E A Dzhambinova

Российский университет дружбы народов

врач травматолог-ортопед, аспирант кафедры травматологии и ортопедии Российского университета дружбы народов

A S Kanaev

Российский университет дружбы народов

доктор медицинских наук, профессор, заведующий кафедрой травматологии, ортопедии и артрологии РУДН

References

  1. Kulkarni R., Pani K., Neuman C et al. Polylactic acid for surgical implants. Arch Surg 1966; 93: 839-843.
  2. Barber F, Elrod B, McGuire D, Paulos L Preliminary results of an absorbable interference screw. Arthroscopy 1995; 11: 573-588.
  3. Brand J., Nyland J., Caborn D., Johnson D. Softtissue interference fixation: bioabsorbable screw versus metal screw. Arthroscopy 2005; 21(8): 911-916
  4. Bostman O. Osteolytic changes accompanying degradation of absorbable fracture fixation implants. J Bone Joint Surg Br 1991; 73: 679-68.
  5. Sanchis-Alfonso V, Tinto-Pedrerol M Femoral interference screw divergence after anterior cruciate ligament reconstruction provoking severe anterior knee pain. Arthroscopy 2004; 20(5): 528-531.
  6. Scioscia T., Giffin J. et al. Potential complication of bioabsorbable screw fixation for osteochondritis dissecans of the knee. Arthroscopy 2001; 17(2): 7-11.
  7. Shafer B., Simonian P. Broken poly-L-lactic acid interference screw after ligament reconstruction. Arthroscopy 2002; 18(7): 35-37.
  8. Tecklenburg K, Burkart P, Hoser C, Rieger M, Fink C. Prospective evaluation of patellar tendon graft fixation in anterior cruciate ligament reconstruction comparing composite bioabsorbable and allograft interference screws. Arthroscopy. 2006; 22: 993-999.
  9. Johnston M, Morse A, Arrington J, Pliner M, Gasser S. Resorption and remodeling of hydroxyapatite-poly-L-lactic acid composite anterior cruciate ligament interference screws. Arthroscopy. 2011; 27:1671-1678.
  10. Ntagiopoulos P., Demey G., Tavernier T., Dejour D. Comparison of.resorption and remodeling of bioabsorbable interference screws in anterior cruciate ligament reconstruction. Int Orthop. 2015; 3: 697-706.
  11. Kontakis G., Pagkalos J., Tosounidis I. et al. Bioabsorbable materials in orthopaedics. Acta Orthop Belg 2007; 73: 159-169.
  12. Bourke H., Salmon L., Waller A. et al. Randomized controlled trial of osteoconductive fixation screws for anterior cruciate ligament reconstruction: a comparison of the Calaxo and Milagro screws. Arthroscopy 2013; 29: 74-82.
  13. Barth J., Akritopoulos P., Graveleau N., Barthelemy R., et al. Efficacy of osteoconductive ceramics in bioresorbable screws for anterior cruciate ligament reconstruction. Orthopaedic Journal of Sports Medicine 2016; 4: 720-724.
  14. Barber E., Doscery W. Long-term absorbtion of poly-L-lactic acid interference screws after anterior cruciate ligament reconstraction. Arthroscopy 2008; 2: 370-373.

Copyright (c) 2016 Zvezdkina E.A., Lesnyak V.N., Akhpashev A.A., Dzhambinova E.A., Kanaev A.S.

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.

This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies