Dead-Time Pseudo-Compensation for Improvement of Accurate Characteristics of a Continuous Control System with Correction According CP a Smith Predictor


Дәйексөз келтіру

Толық мәтін

Ашық рұқсат Ашық рұқсат
Рұқсат жабық Рұқсат берілді
Рұқсат жабық Тек жазылушылар үшін

Аннотация

This paper describes the use of a cascade compensator constructed according to a Smith scheme in the forward loop of a system being designed for the purpose of analyzing the quality of processes in steady states. This can be effectively used to solve the problem of providing the system with a required reserve of stability by placing a dead-time element outside a closed loop. The dead-time effect manifests only when the transient time increases by the value of dead time with no changes in the overshoot value. It is determined that the velocity Q-factor of the system with a cascade compensator constructed according to a Smith scheme theoretically cannot be larger than the reciprocal of the dead time. This paper also demonstrates the possibility of reducing this negative property of the cascade compensator constructed according to a Smith scheme by dead-time pseudo-compensation with the use of differentiating elements.

Авторлар туралы

N. Vunder

Saint Petersburg National Research University of Information Technologies, Mechanics and Optics

Хат алмасуға жауапты Автор.
Email: polinova_nina@mail.ru
Ресей, pr. Kronverskii 49, St. Petersburg, 197101

M. Sinetova

Saint Petersburg National Research University of Information Technologies, Mechanics and Optics

Email: polinova_nina@mail.ru
Ресей, pr. Kronverskii 49, St. Petersburg, 197101

A. Ushakov

Saint Petersburg National Research University of Information Technologies, Mechanics and Optics

Email: polinova_nina@mail.ru
Ресей, pr. Kronverskii 49, St. Petersburg, 197101

Қосымша файлдар

Қосымша файлдар
Әрекет
1. JATS XML

© Allerton Press, Inc., 2018