Rotational angiography and the role of rotational angiography in modern clinical practice
- Authors: Klimov V.P1,2, Azarov A.V1,3, Semitko S.P1,2, Vertkina N.V2
-
Affiliations:
- Institute of Professional Development of FMBA of Russia
- V.V.Veresaev City Clinical Hospital
- Mytischi City Clinical Hospital
- Issue: Vol 19, No 1 (2017)
- Pages: 42-49
- Section: Articles
- URL: https://journals.rcsi.science/2075-1753/article/view/94657
- ID: 94657
Cite item
Full Text
Abstract
Keywords
Full Text
##article.viewOnOriginalSite##About the authors
V. P Klimov
Institute of Professional Development of FMBA of Russia; V.V.Veresaev City Clinical Hospital
Email: vp_klimov@mail.ru
канд. мед. наук, доц. каф. рентгенэндоваскулярных и миниинвазивных методов диагностики и лечения ФГБОУ ДПО ИПК; врач-специалист рентген-эндоваскулярных методов диагностики и лечения ГБУЗ «ГКБ им. В.В.Вересаева» 125371, Russian Federation, Moscow, Volokolamskoe sh., d. 91; 127644, Russian Federation, Moscow, ul. Lobnenskaia, d. 10
A. V Azarov
Institute of Professional Development of FMBA of Russia; Mytischi City Clinical Hospital
Email: azarov_al@mail.ru
канд. мед. наук, доц. каф. рентгенэндоваскулярных и миниинвазивных методов диагностики и лечения ФГБОУ ДПО ИПК; зам. глав. врача, рук. Регионального сосудистого центра ГБУЗ МО МГКБ 125371, Russian Federation, Moscow, Volokolamskoe sh., d. 91; 141009, Russian Federation, Moscow Region, Mytisсhi, ul. Kominterna, d. 24
S. P Semitko
Institute of Professional Development of FMBA of Russia; V.V.Veresaev City Clinical Hospital
Email: semitko@mail.ru
д-р мед. наук, проф., зав. каф. рентгенэндоваскулярных и миниинвазивных методов диагностики и лечения ФГБОУ ДПО ИПК; зав. отд. рентген-эндоваскулярных методов диагностики и лечения ГБУЗ «ГКБ им. В.В.Вересаева» 125371, Russian Federation, Moscow, Volokolamskoe sh., d. 91; 127644, Russian Federation, Moscow, ul. Lobnenskaia, d. 10
N. V Vertkina
V.V.Veresaev City Clinical Hospitalд-р мед. наук, глав. врач ГБУЗ «ГКБ им. В.В.Вересаева» 127644, Russian Federation, Moscow, ul. Lobnenskaia, d. 10
References
- Беленков Ю.Н., Терновой С.К., Синицын В.Е. Магнитно - резонансная томография сердца и сосудов. М.: Видар, 1997; с. 144.
- Синицын В.Е., Дадвани С.А., Артюхина Е.Г. и др. Компьютерная томографическая ангиография в диагностике атеросклеротических поражений аорты и артерий нижних конечностей. Ангиология и сосудистая хирургия. 2000; 2. 37-44.
- Kreuzer S.H, Prokop M, Ahmadi R et al. Grading of carotid artery stenoses with multislice CT-angiography: comparison with DSA. Cardiovasc Intervent Radiol 2001; 24 (Suppl. 1): S160.
- Mallouhi A, Rieger M, Czermak B et al. Renal multi - slice spiral-CT angiography: the role of three - dimensional reconstructions in follow - up of renal artery stenting. Cardiovasc Intervent Radiol 2001; 24 (Suppl. 1): S160.
- Ernemann U, Skalej M, Guervit O et al. 3D-angiography in planning the treatment of cerebral aneurysms. Electromedica 2000; 68: 31-6.
- Paulin S. Coronary angiography, past, present and future. Cardiovasc Interven Radiol 2001; 24: S232-S233.
- Tajima H, Kumazaki T, Gemma K et al. Clinical assessment rotational digital angiography for the diagnosis of aortic dissection. Nippon Igaku Hoshasen Gakkai Zasshi 1990; 50 (Suppl. 12): 1608-10.
- Климов В.П., Щиголев Ю.С., Никитин В.Г. и др. Ротационная цифровая ангиография с субтракцией в диагностике заболеваний головного мозга. В кн.: Неотложная медицинская помощь. Материалы науч. - практ. конф. ГВКГ им. Н.Н.Бурденко. М., 1998; с. 219-20.
- Biederer J, Link J, Peter D et al. Rotational digital subtraction angiography of carotid bifuracation stenosis. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 1999; 171: 283-9.
- Климов В.П., Кучеров В.В., Залесов В.Е. и др. Ротационная цифровая ангиография с субтракцией при определении проходимости аутовенозных аортокоронарных шунтов. В кн.: Неотложная медицинская помощь. Материалы науч. - практ. конф. ГВКГ им. Н.Н.Бурденко. М., 1998; с. 220-1.
- Klein H.M, Vorwerk D, Neuerburg J, Günther R.W. Rotational angiography of the renal arteries. Fortschr Röntgenstr 1995; 162: 249-51.
- Ernemann U, Guervit O, Siekmann R, Skalej M. Rotational angiography: Diagnostic value and application in iterventional neurology. Cardiovasc Interven Radiol 2001; 24 (Suppl. 1): S109-S110.
- Klimov V, Ardashev A. Advantages of rotational DSA in the assessment of ascending aorta in post-CABG angina patients. Eur Radiol 2003; 13 (10): H24.
- Waggershauser T. Digital subtraction rotational angiography (dynavision plus) in clinical application. Electromedica 1998; 66 (Suppl. 5): 2-7.
- Elgersma O.E, Buijs P.S, Wust A.F et al. Maximum internal carotid arterial stenosis: assessment with rotational angiography versus conventional intraarterial digital subtraction angiography. Radiology 1999; 213: 777-83.
- Климов В.П. Эффективность использования ротационной дигитальной субтракционной ангиографии при селективном рентгеноконтрастном исследовании проходимых аутовенозных аортокоронарных шунтов у больных ИБС после операции аортокоронарного шунтирования: экономический аспект. Бюллетень НЦССХ им. А.Н.Бакулева РАМН. 2003; 4 (6): 176.
- Takahashi M, Ozawa Y. Routine biplane cerebral angiography with stereoscopic magnification. Radiology 1980; 136: 113-7.
- Thron A, Voigt K. Rotational cerebral angiography: procedure and value. Am J Neurorad 1983; 4: 289-91.
- Voigt K, Stoeter P, Petersen D. Rotational cerebral roentgenography. Evaluation of the technical procedure and diagnostic application with model studies. Neuroradiology 1975; 10: 95-100.
- Cornelis G, Bellet A, Van Eygen B et al. Rotational multiple sequence roentgenography of intracranial aneurysms. Acta radiol 1972; 13: 74-6.
- Tu R.K, Cohen W.A, Maravilla K.R et al. Digital subtraction rotational angiography for aneurysms of the intracranial anterior circulation: injection method and optimization. Am J Neurorad 1996; 17: 1127-36.
- Gattoni F, Sacrini A, Tonolini M et al. Digital rotational angiography in the study of vascular diseases: technical note and initial clinical applications. Radiol Med (Torino) 1998; 96: (Suppl. 6): 570-3.
- Климов В.П. Возможности ротационной дигитальной субтракционной ангиографии при исследовании аутовенозных аортокоронарных шунтов и коронарных артерий у больных ишемической болезнью сердца. Автореф. дисс. … канд. мед. наук. М., 2004; с. 102.
- Bosanac Z, Miller R.J, Jain M. Rotational digital subtraction carotid angiography: technique and comparison with static digital subtraction angiography. Coin Radiol 1998; 53 (Suppl. 9): 682-7.
- Ashina K. Clinical evaluation of biplane rotational DSA for intracranial diseases. Nippon Igaku Hoshasen Gakkai Zasshi 1994; 54 (Suppl. 13): 1225-36.
- Bullitt E, Soltys M, Chen J et al. Three - dimensional reconstruction of intracranial vessels from biplan projection views. J Neurosci Methods 1996; 66 (Suppl. 1): 13-22.
- Carsin M, Chabert E, Croci S et al. The role of 3-dimensional reconstructions angiographic evaluation of cerebral vascular malformations: 3D morphometry. J Neuroradiol 1997; 24 (Suppl. 2): 137-40.
- Ernemann U, Skalej M, Barth K, Voigt K. 3D-reconstructions of intracranial vessels bassed on rotational angiography. Neuroradiology 1998; 40 (Suppl. 1): 47.
- Bullitt E, Liu A. Aylward S.R et al. Registration of 3D cerebral vessels with 2D digital angiograms: clinical evaluation. Acad Radiol 1999; 6 (Suppl. 9): 539- 46.
- Hoff D.J, Wallace M.C, ter Brugge K.G, Gentili F. Rotational angiography assessment of cerebral aneurysms. Am J Neuroradiol 1994; 15 (Suppl. 10): 1945-1948.
- Tanoue S, Kiyosue H, Kenai H et al. Three - dimensional reconstructed images after rotational angiography in the evaluation of intracranial aneurysms: surgical correlation. Neurosurgery 2000; 47 (Suppl. 4): 866-71.
- Shimizu T, Kodama Y, Endo H et al. The usefulness of three - dimensional reconstructed image by rotational DSA for transcatheter arterial embolization. Cardiovasc Interven Radiol 2001; 24 (Suppl. 1): S169.
- Tajima H, Kumazaki T, Gemma K et al. Rotational digital angiography of ulcer - like projection of pelvis. Radiat Med 1996; 14: 49-51.
- Klimov V, Ardashev A. Rotational DSA of coronary artery as a movable object - if it is possible? Eur Radiol 2004; 14: R31.
- Blendea D et al. Usefulness of high - speed rotational coronary venous angiography during cardiac resynchronization therapy. Am J Cardiol 2007; 100 (10): 1561-5.
- Fagih A.A et al. An initiative to minimize amount of contrast media utilizing a novel rotational coronary sinus occlusive venography technique with ordinary cath - lab X-ray machine during CRT implantation. J Invasive Cardiol 2010; 22 (9): 428-31.
- Klimov V, Ardashev A. Rotational DSA of coronary artery bypass graft patency. Eur Radiol 2003; 13 (10): H26.
- Asato T, Tajima H. Clinical assessment of rotational digital angiography for the diagnosis of hepatocellular carcinoma. Nippon Ika Daigaku Zasshi 1997; 64 (Suppl. 5): 401-10.
- Kumazaki T. Development of a new digital angiography system - improvement of rotational angiography and three dimensional image display. Nippon Igaku Hoshasen Gakkai Zasshi 1991; 51(Suppl. 9): 1068-77.
- Schueler B.A, Sen A. Hsiung H.H, Latchaw R.E, Hu X. Three - dimensional vascular reconstruction with a clinical x - ray angiography system. Acad Radiol 1997; 4 (Suppl. 10): 693-699.
- Bidaut L.M, Laurent C, Piotin M et al. Second - generation three - dimensional reconstruction for rotational three - dimensional angiography. Acad Radiol 1998; 5 (12): 836-49.
- Fahrig R, Nikolov H, Fox A.J, Holdsworth D.W. A three - dimensional cerebrovascular flow phantom. Med Phys 1999; 26 (Suppl. 8): 1589-99.
- Talukdar A.S, Wilson D.L. Modeling and optimization of rotational C-arm stereoscopic X-ray angiography. IEEE Trans. Med Imaging 1999; 18 (Suppl. 7): 604-16.
- Fahrig R, Fox A, Lownie S, Holdsworth D. Use of a C-arm system to generate true three - dimensional computed rotational angiograms: preliminary in vitro and in vivo results. AJNR 1997; 18: 1507-14.
- Unger B, Link J, Trenkler J, Bohm-Jurkovic H. Digital rotational angiography for the preoperative and preinterventional clarification of cerebral arterial aneurysms. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr 1999; 170 (Suppl. 5): 482-91.
- Missler Y, Hundt C, Wiesmann M et al. Three - dimensional reconstructed rotational digital subtraction angiography in planning treatment of intracranial aneurysms. Eur Radiol 2000; 10 (Suppl. 4): 564-8.
- Endo H, Shimizu T, Kodama Y et al. Usefulness of three - dimensional (3D) recostructed images of renal arteries. Cardiovasc Intervent Radiol 2001; 24 (Suppl. 1): S196.
- Kofune M et al. Three - dimensional reconstruction of the coronary sinus with rotational angiography. Circulation J 2008; 72 (6): 1020-21.
- Gutleben K.J et al. Three - dimensional coronary sinus reconstruction - guided left ventricular lead implantation based on intraprocedural rotational angiography: a novel imaging modality in cardiac resynchronization device implantation. Europace 2011; 13 (5): 675-82.