The current status of transcatheter heart valve replacement, using the valve-in-valve technique
- Authors: Imaev T.E1, Komlev A.E1, Kolegaev A.S1, Lepilin P.M1, Akchurin R.S1
-
Affiliations:
- A.L.Myasnikov Institute of Clinical Cardiology, Russian Cardiological Scientific-Industrial Complex of the Ministry of Health of the Russian Federation
- Issue: Vol 18, No 5 (2016)
- Pages: 89-92
- Section: Articles
- URL: https://journals.rcsi.science/2075-1753/article/view/94497
- ID: 94497
Cite item
Full Text
Abstract
Full Text
##article.viewOnOriginalSite##About the authors
T. E Imaev
A.L.Myasnikov Institute of Clinical Cardiology, Russian Cardiological Scientific-Industrial Complex of the Ministry of Health of the Russian Federation
Email: imaev.timur@mail.ru
канд. мед. наук, вед. науч. сотр. лаб. гибридных методов лечения сердечно-сосудистых заболеваний отд. сердечно-сосудистой хирургии ИКК им. А.Л.Мясникова ФГБУ РКНПК 121552, Russian Federation, Moscow, ul. 3-ia Cherepkovskaia, d. 15a
A. E Komlev
A.L.Myasnikov Institute of Clinical Cardiology, Russian Cardiological Scientific-Industrial Complex of the Ministry of Health of the Russian Federationврач-кардиолог ОССХ ИКК им. А.Л.Мясникова ФГБУ РКНПК 121552, Russian Federation, Moscow, ul. 3-ia Cherepkovskaia, d. 15a
A. S Kolegaev
A.L.Myasnikov Institute of Clinical Cardiology, Russian Cardiological Scientific-Industrial Complex of the Ministry of Health of the Russian Federationканд. мед. наук, науч. сотр. лаб. гибридных методов лечения сердечно-сосудистых заболеваний отд. сердечно-сосудистой хирургии ИКК им. А.Л.Мясникова ФГБУ РКНПК 121552, Russian Federation, Moscow, ul. 3-ia Cherepkovskaia, d. 15a
P. M Lepilin
A.L.Myasnikov Institute of Clinical Cardiology, Russian Cardiological Scientific-Industrial Complex of the Ministry of Health of the Russian Federationканд. мед. наук, ст. науч. сотр. лаб. гибридных методов лечения сердечно-сосудистых заболеваний отд. сердечно-сосудистой хирургии ИКК им. А.Л.Мясникова ФГБУ РКНПК 121552, Russian Federation, Moscow, ul. 3-ia Cherepkovskaia, d. 15a
R. S Akchurin
A.L.Myasnikov Institute of Clinical Cardiology, Russian Cardiological Scientific-Industrial Complex of the Ministry of Health of the Russian Federationакад. РАН, д-р мед. наук, проф., рук. отд. сердечно-сосудистой хирургии ИКК им. А.Л.Мясникова ФГБУ РКНПК 121552, Russian Federation, Moscow, ul. 3-ia Cherepkovskaia, d. 15a
References
- Raval J, Nagaraja V, Eslick G.D, Denniss A.R. Transcatheter Valve - in - Valve Implantation: A Systematic Review of Literature. Heart, Lung and Circulation 2014; 23: 1020-8.
- Gurvitch R, Cheung A, Wood D.A et al. Transcatheter. Valve - in - Valve Implantation for Failed Surgical Bioprosthetic Valves. J Am Coll Cardiol 2011; 58 (21).
- Bapat V, Mydin I, Chadalavada S et al. A Guide to Fluoroscopic Identification and Design of Bioprosthetic Valves: A Reference for Valve - in - Valve Procedure. Cathet Cardiovasc Int doi: 10.1002/ccd.
- Piazza N, Bleiziffer S, Brockmann G et al. Transcatheter Aortic Valve Implantation for Failing Surgical Aortic Bioprosthetic Valve. J Am Coll Cardiol Intv 2011; 4 (7): 721-32.
- Piazza N, Bleiziffer S, Brockmann G et al. Transcatheter Aortic Valve Implantation for Failing Surgical Aortic Bioprosthetic Valve: From Concept to Clinical Application and Evaluation (Part 2). JACC: Cardiovascular Interventions 2011; 4 (7): 733-42.
- Descoutures F, Himbert D, Maisano F et al. Transcatheter valve - in - ring implantation after failure of surgical mitral repair. Eur J Cardiothorac Surg 2013; 44 (1): e8-15.
- Silberman S, Oren A, Dotan M. Aortic valve replacement: choice between mechanical valves and bioprostheses. J Card Surg 2008; 23: 299-306.
- Brown J.M, O'Brien S.M, Wu C et al. Isolated aortic valve replacement in North America comprising 108,687 patients in 10 years: changes in risks, valve types, and outcomes in the Society of Thoracic Surgeons National Database. J Thorac Cardiovasc Surg 2009; 137: 82-90.
- Vogt P.R, Brunner-La Rocca H, Sidler P. Reoperative surgery for degenerated aortic bioprostheses: predictors for emergency surgery and reoperative mortality. Eur J Cardiothorac Surg 2000; 17: 134-9.
- Jones J.M, O'Kane H, Gladstone D.J. Repeat heart valve surgery: risk factors for operative mortality. J Thorac Cardiovasc Surg 2001; 122: 913-8.
- Ruel M, Kulik A, Rubens F.D. Late incidence and determinants of reoperation in patients with prosthetic heart valves. Eur J Cardiothorac Surg 2004; 25: 364-70.
- Jaussaud N, Gariboldi V, Giorgi R. Risk of reoperation for aortic bioprosthesis dysfunction. J Heart Valve Dis 2009; 18: 256-61.
- Wenaweser P, Buellesfeld L, Gerckens U, Grube E. Percutaneous aortic valve replacement for severe aortic regurgitation in degenerated bioprosthesis: the first valve in valve procedure using the CoreValve revalving system. Cathet Cardiovasc Int 2007; 70: 760-4.
- Pasic M, Unbehaun A, Dreysse S et al. Transapical aortic valve implantation after previous aortic valve replacement: clinical proof of the ‘‘valve - in - valve’’ concept. J Thorac Cardiovasc Surg 2011; 142: 270-7.
- Kempfert J, Van Linden A, Linke A et al. Transapical off - pump valve - in - valve implantation in patients with degenerated aortic xenografts. Ann Thorac Surg 2010; 89: 1934-41.
- Dvir D, Webb J, Brecker S et al. Transcatheter aortic valve replacement for degenerative bioprosthetic surgical valves: results from the global valve - in - valve registry. Circulation 2012; 126: 2335-44.
- Bonow R.O, Carabello B.A, Chatterjee K et al. ACC/AHA 2006 guidelines for the management of patients with valvular heart disease: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (writing Committee to Revise the 1998 guidelines for the management of patients with valvular heart disease) developed in collaboration with the Society of Cardiovascular Anesthesiologists endorsed by the Society for Cardiovascular Angiography and Interventions and the Society of Thoracic Surgeons. J Am Coll Cardiol 2006; 48: e1-e148.
- Bruschi G, Barosi A, Colombo P et al. Direct transatrial transcatheter SAPIEN valve implantation through right minithoracotomy in a degenerated mitral bioprosthetic valve. Ann Thorac Surg 2012; 93: 1708-10.
- Montorfano M, Latib A, Chieffo A et al. Successful Percutaneous Anterograde Transcatheter Valve - in - Valve Implantation in the Mitral Position. JACC: Cardiovascular Interventions 2011; 4: 1246-7.
- Webb J.G, Wood D.A, Ye J et al. Transcatheter valve - in - valve implantation for failed bioprosthetic heart valves. Circulation 2010; 121: 1848-57.
- Cheung A.W, Gurvitch R, Ye J et al. Transcatheter transapical mitral valve - in - valve implantations for a failed bioprosthesis: a case series. J Thorac Cardiovasc Surg 2011; 141: 711-5.