Constant phase elements (CPE) are widely used in fitting of electrochemical impedance spectra instead of ideal capacitances. The present work begins with a discussion of two commonly used models for conversion of the CPE parameters to an effective capacitance, i.e. Hsu and Mansfeld’s and Brug et al.’s; and then continues with presenting alternative geometric assumptions to derive some other formulae. Afterward, it provides a comparison between the results of the formulae together with comments on their applications. Through discussing the relation between the models, this work offers a better understanding of the mathematics of impedance exhibiting frequency dispersion.