Development of a digital fabrication device for the manufacture of removable dentures

Cover Page

Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

BACKGROUND: Digital technologies such as those used to manufacture complete removable dentures have become widely popular in the field of dentistry. The fabrication of an accurate, monolithic removable denture where the teeth and base are made using subtractive or additive technologies is crucial.

AIM: The aim of the current study was to develop a device that permits manufacture of removable dentures using digital technologies.

MATERIAL AND METHODS: The article describes modern methods of manufacturing complete removable dentures.

RESULTS: With the help of digital technologies, it was possible to obtain a monolithic prosthesis made of plastic, eliminating inaccuracies in the positioning of teeth during placement in the basis of the prosthesis, as well as to connect the basis of the prosthesis and teeth using acrylic plastic. Additionally, a brief description of the basic tools and materials necessary for this technique have also been provided.

CONCLUSION: The advantages of digitally manufacturing complete removable dentures include high accuracy, absence of overbite, high speed, and minimal shrinkage. These benefits allow us to conclude that the use of digital protocols for the manufacture of complete removable dentures is essential in order to achieve favorable treatment outcomes that meet the expectations of the doctor and the needs of the patient.

About the authors

Matvey S. Terechov

RUDN University

Email: matter25@mail.ru

postgraduate student

Russian Federation, Moscow

Viktoriya A. Semenova

RUDN University

Email: dr.vsemenova@yandex.ru
Russian Federation, Moscow

Samvel V. Apresyan

RUDN University

Author for correspondence.
Email: dr.apresyan@gmail.com
ORCID iD: 0000-0002-3281-707X

MD, Dr. Sci. (Med.), Professor, dentist

Russian Federation, Moscow

Alexander G. Stepanov

RUDN University

Email: stepanovmd@list.ru
ORCID iD: 0000-0002-6543-0998

MD, Dr. Sci. (Med.), Professor, dentist

Russian Federation, Moscow

Pavel L. Kravets

RUDN University

Email: pashatex83@gmail.com

dental technician

Russian Federation, Moscow

References

  1. Apresyan SV. Digital planning of orthopedic dental treatment. Russian Dental Journal. 2019;23(3–4):158–164. (In Russ). doi: 10.18821/1728-2802-2019-23-3-4-158-164
  2. Steinmassl PA, Klaunzer F, Steinmassl O, et al. Evaluation of Currently Available CAD/CAM Denture Systems. Int J Prosthodont. 2017;30(2):116–122. doi: 10.11607/ijp.5031
  3. Srinivasan M, Cantin Y, Mehl A, et al. CAD/CAM milled removable complete dentures: an in vitro evaluation of trueness. Clin Oral Investig. 2017;21(6):2007–2019. doi: 10.1007/s00784-016-1989-7
  4. Radford DR, Juszczyk AS, Clark RK. The bond between acrylic resin denture teeth and the denture base: recommendations for best practice. Br Dent J. 2014;216(4):165–167. doi: 10.1038/sj.bdj.2014.99
  5. Clements JL, Tantbirojn D, Versluis A, Cagna DR. Do denture processing techniques affect the mechanical properties of denture teeth? J Prosthet Dent. 2018;120(2):246–251. doi: 10.1016/j.prosdent.2017.10.02
  6. Goodacre BJ, Goodacre CJ, Baba NZ, Kattadiyil MT. Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques. J Prosthet Dent. 2018;119(1):108–115. doi: 10.1016/j.prosdent.2017.02.009
  7. Lee S, Hong SJ, Paek J, et al. Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method. J Adv Prosthodont. 2019;11(1):55–64. doi: 10.4047/jap.2019.11.1.55
  8. Meneghihi A, Mazzarella S, Di Franco A. Full upper and lower duplicate dentures using Vertysystem Furbo. GAP Australasian-Dentist-May. June 2019. P. 82–84.
  9. Patent RUS №2722458/ 01.06.2020 Byul, №16, MPK:A61C13/00. Apresyan SV, Kravets PL. “Ustroystvo dlya izgotovleniya zubnykh protezov”: № 2020107773 (In Russ).
  10. Vertysystem.com [Internet]. [cited: 2021 Dec 20]. Доступ по ссылкe: https://www.vertysystem.com/us/assets/kit-vertysystem-full-denture_en.pdf
  11. Trasformersystem.com [Internet]. All-in Spacer Package Descrition. [cited: 2021 Dec 20]. Available from: http://www.trasformersystem.com/all-in-en/
  12. Kurlyandskiy VY. Guide to practical classes in orthopedic dentistry. Third edition. Moscow: Medicine; 1973. (In Russ).
  13. Lebedenko IY, Kalivrajiyan ES, Ibragimov TI. Manual of orthopedic dentistry. Prosthetics in the complete absence of teeth. Moscow: Medicine; 2005. (In Russ).

Supplementary files

Supplementary Files
Action
1. JATS XML
2. Fig. 1. Verticulator for the manufacture of removable dentures in digital manufacturing technology

Download (72KB)
3. Fig. 2. Verticulator for the manufacture of removable dentures in digital manufacturing technology with an additional platform

Download (111KB)
4. Fig. 3. Virtual image of the prototype of a removable denture in the Exocad program

Download (97KB)
5. Fig. 4. Polymer prototype of a removable denture made by 3D printing

Download (58KB)
6. Fig. 5. Virtual placement of teeth in the Exocad program

Download (118KB)
7. Fig. 6. The milled basis of the prosthesis made of a polymer of a red-pink polymer, the color corresponding to the color of the gum

Download (127KB)
8. Fig. 7. The polymer prototype of the prosthesis is fixed in a verticulator for replication

Download (124KB)
9. Fig. 8. Permanent prosthesis made using the developed device

Download (108KB)

Copyright (c) 2021 Eco-Vector


 


Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».