The term "glaucoma" unites a large group of eye diseases with a characteristic pathogenesis and clinical picture, but different aetiology. Modern classifications group the different forms of glaucoma according to origin, age of the patient, mechanism of intraocular pressure increase and its level, degree of optic disc damage and course of the disease. The disease is a significant medical and social problem, as it affects large population groups worldwide and is the leading cause of irreversible blindness. Every year the number of glaucoma patients of working age increases, and the presence of concomitant diseases in patients complements and complicates the clinical picture and course of the main pathological process. To date, high therapeutic effectiveness of electromagnetic fields in glaucoma treatment has been determined and proved, specific methods of procedures have been developed, and the list of indications for their prescription is expanding.

The purpose of the review is to present the possibilities of using transcranial magnetic therapy in the treatment of glaucoma.

The authors, based on available scientific data and their own clinical observations, summarizes information regarding the use of transcranial magnetic therapy for glaucoma. Indications and contraindications for transcranial magnetic therapy are outlined. The principles of prescribing various methods of transcranial magnetic therapy are covered in detail. The characteristics of the equipment used for transcranial magnetic therapy procedures are given.

In general, physical therapeutic factors play an important role in the overall complex of therapeutic and preventive measures in the treatment of eye diseases. As methods of external influence they have a direct impact on etiological and pathogenetic mechanisms, as well as on the symptoms of the disease.

About the authors

Marina Yu. Gerasimenko

Russian Medical Academy of Continuous Professional Education

Author for correspondence.
Email: mgerasimenko@list.ru
ORCID iD: 0000-0002-1741-7246
SPIN-code: 7625-6452

MD, Dr. Sci. (Med.), Professor

Russian Federation, Moscow

Larisa K. Moshetova

Russian Medical Academy of Continuous Professional Education

Email: moshetovalk@yandex.ru
ORCID iD: 0000-0002-5899-2714
SPIN-code: 5697-6825

MD, Dr. Sci. (Med.), Professor, Academician of the Russian Academy of Sciences

Russian Federation, Moscow

Igor B. Аlexeev

Russian Medical Academy of Continuous Professional Education

Email: ialekseev63@mail.ru
ORCID iD: 0000-0002-4506-4986
SPIN-code: 4696-5937

MD, Dr. Sci. (Med.), Professor

Russian Federation, Moscow

Irina V. Vorobyeva

Russian Medical Academy of Continuous Professional Education

Email: irina.docent2000@mail.ru
ORCID iD: 0000-0003-2707-8417
SPIN-code: 1693-3019

MD, Dr. Sci. (Med.), Professor

Russian Federation, Moscow

Tatiana N. Zaytseva

Russian Medical Academy of Continuous Professional Education

Email: zaytn@mail.ru
ORCID iD: 0000-0001-7123-1568
SPIN-code: 9416-4428

MD, Cand. Sci. (Med.)

Russian Federation, Moscow

Inna S. Evstigneeva

Russian Medical Academy of Continuous Professional Education

Email: evstigneevais@mail.ru
ORCID iD: 0000-0001-9128-0965
SPIN-code: 5163-7726

MD, Cand. Sci. (Med.), Associate Professor

Russian Federation, Moscow

References

  1. Tanito M, Kaidzu S, Takai Y, Ohira A. Association between systemic oxidative stress and visual field damage in open-angle glaucoma. Sci Rep. 2016;6:25792. doi: 10.1038/srep25792
  2. Wójcik-Gryciuk A, Małgorzata S, Waleszczykb JW. Glaucoma: State of the art and perspectives on treatment. Restor Neurol Neurosci. 2016;34(1):107–123. doi: 10.3233/RNN-150599
  3. Kursheva NI, Parshunina OA, Arjenevnishvili TD, et al. New diagnostic markers of glaucoma. Novosti glaukomy. 2015;(1):131–133. (In Russ). EDN: TWDIQL
  4. Kurysheva NI. Perimetry in diagnostics of glaucoma optic neuropathy. Moscow: Grinlait; 2015. 85 p. (In Russ).
  5. National glaucoma manual. Ed. by E.A. Egorov, Y.S. Astakhov, V.P. Yerichev. 3rd ed. Moscow: GEOTAR-Media; 2015. 452 p. (In Russ).
  6. Erichev VP, Petrov SYu, Kozlova IV, et al. Modern methods of functional diagnostics and monitoring of glaucoma. Part 1. Perimetry as a functional diagnostics method. National J Glaucoma. 2015;14(2):75–81. (In Russ).
  7. Allocco AR, Ponce JA, Riera MJ, Magurno MG. Critical pathway for primary open angle glaucoma diagnosis. Int J Ophthalmol. 2017;10(6):968–972. doi: 10.18240/ijo.2017.06.21
  8. Astakhov YuS, Butin YeV, Morozova NV, et al. An experience of retinalamin use in glaucomatous optic neuropethy and age-related macular degeneration. Ophthalmology J. 2013;6(2):45–49. EDN: RACMSZ
  9. Moshetova LK, Zharov VV, Maksimov IB, Naigovzina NK. Ways to improve the efficiency of the state ophthalmological hospital of the subject of the Russian Federation. Problemy oftal'mologii. 2004;(1):10–13. EDN: ZIRTZR
  10. Nesterov AP. Glaucoma. 2nd ed., revision. Moscow: Meditsinskoe informatsionnoe agentstvo; 2008. 357 p. (In Russ).
  11. Leske MC, Heijl A, Hussein M, et al. Factors for glaucoma progression and the effect of treatment: The early manifest glaucoma trial. Arch Ophthalmol. 2003;121(1):48–56. doi: 10.1001/archopht.121.1.48
  12. Kunin VD, Redid AA. Glaucoma dynamics in patients who followed monitoring and treatment instructions and in those who didn't. Russ Ann Ophthalmology. 2013;129(2):61–66. EDN: PYNXHH
  13. Sychev DA, Moshetova LK. Clinical and pharmacological aspects of combined pathology: cardiovascular diseases and glaucoma. National J Glaucoma. 2014;13(2):99–104. EDN: SMYHMB
  14. Song BJ, Aiello LP, Pasquale LR. Presence and risk factors for glaucoma in patients with diabetes. Curr Diab Rep. 2016;16(12):124. doi: 10.1007/s11892-016-0815-6
  15. Ophthalmology. National manual. Ed. by S.E. Avetisov, E.A. Egorov, L.K. Moshetova, et al. Moscow: GEOTAR-Media; 2019. 752 p. (In Russ).
  16. Guo MW, Wu YY, Liang ZB. Hyaluronic acid increases MMP-2 and MMP-9 expressions in cultured trabecular meshwork cells from patients with primary open-angle glaucoma. Mol Vis. 2012;18:1175–1181.
  17. Saccà SC, Gandolfi S, Bagnis A, et al. From DNA damage to functional changes of the trabecular meshwork in aging and glaucoma. Ageing Res Rev. 2016;29:26–41. doi: 10.1016/j.arr.2016.05.012
  18. He M, Wang W, Han X, Huang W. Matrix metalloproteinase-1 rs1799750 polymorphism and glaucoma: A meta-analysis. Ophthalmic Genet. 2017;318(3):211–216. doi: 10.1080/13816810.2016.1193877
  19. Greco A, Rizzo MI, de Virgilio A, et al. Emerging concepts in glaucoma and review of the literature. Am J Med. 2016;129(9):1000.e7–1000.e13. doi: 10.1016/j.amjmed.2016.03.038
  20. Avetisov SE, Erichev VP, Antonov AA. Diagnostic capabilities of transpalpebral tonometry with IGD-03. National J Glaucoma. 2016;15(3):17–23. EDN: WMIPRF
  21. Yartsev AV, Strakhov VV, Alekseev VV, Khlyaf VB. Study of the outer retinal layers in patients with primary glaucoma. Novosti glaukomy. 2014;(1):3–5. (In Russ).
  22. Yurova OV, Nazarova GA, Konchugova TV, et al. Device-assisted physical therapy in medical rehabilitation of patients with ophthalmological disorders. Doctor.Ru. 2014;(13):50–55. EDN: TKIPOD
  23. Loskutov IA, Karpova NA. Physiotherapy in treatment of primary open angle glaucoma. Zemskii vrach. 2012;(3):15–16. EDN: OYRPYP
  24. Egorov EA, Kamenskih ID, Raigorodsky YuM, et al. The results of trans-cranial application of the low-intensity magneto-laser treatment in the patients presenting with primary open-angle glaucoma. Russ J Physical Therapy, Balneotherapy Rehabilitation. 2013;(5):15–18. EDN: RVQRIF
  25. Borzunov OI. Pathogenetic substantiation of the physical factors usage in patients with the distrophic ophthalmopathology (review). Resort medicine. 2017;(3):197–203. EDN: ZMQKYH
  26. Makogon SI, Makogon AS. The possibilities of physiotherapeutic methods of treatment of patients of elderly and senile age with primary open angle glaucoma (review of literature). Clinical gerontology. 2018;24(9-10):37–39. EDN: XWBNLN
  27. Kantarzhi EP. Physical therapy and combined treatment of elderly patients with glaucoma, ophtalmohypertension and suspected glaucoma. Clinical gerontology. 2008;14(7):39–41. EDN: JTYOAX
  28. Lyadov MV. The application of general air cryotherapy for the combined treatment of the patients presenting with primary open-angle glaucoma. Russ J Physical Therapy, Balneotherapy Rehabilitation. 2014;(1):51–52. EDN: RVQRZD
  29. Tumanova AL. Sanatorium resort prevention and rehabilitation of eye disorders. Resort medicine. 2017;(4):114–117. EDN: XQYGNF
  30. Ota Y, Ozeki N, Yuki K, et al. The efficacy of transcorneal electrical stimulation for the treatment of primary open-angle glaucoma: A pilot study. Keio J Med. 2018;67(3):45–53. doi: 10.2302/kjm.2017-0015-OA
  31. Röck T, Naycheva L, Willmann G, et al. Transcorneal electrical stimulation in primary open angle glaucoma. Ophthalmologe. 2017;114(10):922–929. doi: 10.1007/s00347-016-0415-5
  32. Drakon AK, Korchazhkina NB. Modern methods magnetotherapy in patient with primary open-angle glaucoma. J New Medical Technologies. 2011;18(4):230–231. EDN: OMHIOT
  33. Patent RUS № RU 2269986 C1. Gerasimenko MYu, Ryabtseva AA, Filatova EV, et al. Method of treatment of patients with glaucoma. (In Russ). Available from: https://yandex.ru/patents/doc/RU2269986C1_20060220?ysclid=lym0yjqysv198886463. Accessed: 15.01.2024.
  34. Physiotherapy and spa treatment: A manual. In 3 volumes. Ed. by V.M. Bogolyubov. Moscow: Binom; 2012. EDN: QMBMEJ
  35. Martynova NO. Prospects for the treatment of open angle glaucoma by transcranial magnetic therapy. Russ J Physical Therapy, Balneotherapy Rehabilitation. 2013;(5):49–50. EDN: RVQRNF
  36. Kamenskih TG, Veselova EV, Kamenskih ID. Comparison of different methods of physiotherapy treatment in the management of primary open-angle glaucoma. Almanac Clinical Med. 2015;(36):40–46. EDN: TMUWBZ
  37. Makashova NV, Ivanishchev KV. Clinical results of transpalpebral tonometry. National J Glaucoma. 2013;(2):42–46. EDN: RSNONJ
  38. Tugeeva EE, Voroncova TN. Possibilities of using the TVHD-01 transpalpebral tonometer in paediatric ophthalmological practice. Russ J Clin Ophthalmol. 2013;13(2):61–63. (In Russ). EDN: QZYWZR
  39. Valeeva RR. Main types of electronic tonometrs (literature review). Vestnik Bashkirskogo gosudarstvennogo medicinskogo universiteta. 2017;(3):34–38. EDN: PHKYAB
  40. Egorov EA, Romanova TB, Kac DV, et al. Transpalpebral tonometry is a promising method for monitoring intraocular pressure. Russ J Clin Ophthalmol. 2016;16(2):75–78. (In Russ). EDN: ZNOFTD

Supplementary files

Supplementary Files
Action
1. JATS XML
2. Fig. 1. View of a normal optic nerve head.

Download (7KB)
3. Fig. 2. Normal discs: on the left is a small disc with low excavation (a) and on the right is a larger disc with proportionally more excavation (b).

Download (146KB)
4. Fig. 3. Nonspecific signs of glaucomatous damage: disc hemorrhages (a, b); exposure of the lower circumference of blood vessels (с); kinking of blood vessels (d, e); loss of the neuroretinal rim in the nasal quadrant (f).

Download (484KB)
5. Fig. 4. Excitation of inductors (from the 1st inductor to the 6th) of flexible radiating lines.

Download (10KB)
6. Fig. 5. Placement of the emitter on the patient’s head for transcranial magnetotherapy of the brain.

Download (27KB)
7. Fig. 6. Location of ТВГД-2 in the area of the edge of the upper eyelid.

Download (15KB)
8. Fig. 7. Location of ТВГД-2 in the crease of the upper eyelid.

Download (16KB)

Copyright (c) 2023 Eco-Vector

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
 


Согласие на обработку персональных данных с помощью сервиса «Яндекс.Метрика»

1. Я (далее – «Пользователь» или «Субъект персональных данных»), осуществляя использование сайта https://journals.rcsi.science/ (далее – «Сайт»), подтверждая свою полную дееспособность даю согласие на обработку персональных данных с использованием средств автоматизации Оператору - федеральному государственному бюджетному учреждению «Российский центр научной информации» (РЦНИ), далее – «Оператор», расположенному по адресу: 119991, г. Москва, Ленинский просп., д.32А, со следующими условиями.

2. Категории обрабатываемых данных: файлы «cookies» (куки-файлы). Файлы «cookie» – это небольшой текстовый файл, который веб-сервер может хранить в браузере Пользователя. Данные файлы веб-сервер загружает на устройство Пользователя при посещении им Сайта. При каждом следующем посещении Пользователем Сайта «cookie» файлы отправляются на Сайт Оператора. Данные файлы позволяют Сайту распознавать устройство Пользователя. Содержимое такого файла может как относиться, так и не относиться к персональным данным, в зависимости от того, содержит ли такой файл персональные данные или содержит обезличенные технические данные.

3. Цель обработки персональных данных: анализ пользовательской активности с помощью сервиса «Яндекс.Метрика».

4. Категории субъектов персональных данных: все Пользователи Сайта, которые дали согласие на обработку файлов «cookie».

5. Способы обработки: сбор, запись, систематизация, накопление, хранение, уточнение (обновление, изменение), извлечение, использование, передача (доступ, предоставление), блокирование, удаление, уничтожение персональных данных.

6. Срок обработки и хранения: до получения от Субъекта персональных данных требования о прекращении обработки/отзыва согласия.

7. Способ отзыва: заявление об отзыве в письменном виде путём его направления на адрес электронной почты Оператора: info@rcsi.science или путем письменного обращения по юридическому адресу: 119991, г. Москва, Ленинский просп., д.32А

8. Субъект персональных данных вправе запретить своему оборудованию прием этих данных или ограничить прием этих данных. При отказе от получения таких данных или при ограничении приема данных некоторые функции Сайта могут работать некорректно. Субъект персональных данных обязуется сам настроить свое оборудование таким способом, чтобы оно обеспечивало адекватный его желаниям режим работы и уровень защиты данных файлов «cookie», Оператор не предоставляет технологических и правовых консультаций на темы подобного характера.

9. Порядок уничтожения персональных данных при достижении цели их обработки или при наступлении иных законных оснований определяется Оператором в соответствии с законодательством Российской Федерации.

10. Я согласен/согласна квалифицировать в качестве своей простой электронной подписи под настоящим Согласием и под Политикой обработки персональных данных выполнение мною следующего действия на сайте: https://journals.rcsi.science/ нажатие мною на интерфейсе с текстом: «Сайт использует сервис «Яндекс.Метрика» (который использует файлы «cookie») на элемент с текстом «Принять и продолжить».