Energy Efficiency of Low-Temperature Deaeration of Makeup Water for a District Heating System


Citar

Texto integral

Acesso aberto Acesso aberto
Acesso é fechado Acesso está concedido
Acesso é fechado Somente assinantes

Resumo

It is shown that the temperature of makeup water in district heating systems has a strong effect on the energy efficiency of turbines of thermal power plants. A low-temperature deaeration process that considerably improves the energy efficiency of thermal power plants is developed. The desorbing agent is the gas supplied to the burners of the boiler. The energy efficiency of the process for a typical unit of thermal power plant is assessed.

Sobre autores

V. Sharapov

Ulyanovsk State Technical University

Autor responsável pela correspondência
Email: vlad-sharapov2008@yandex.ru
Rússia, Ulyanovsk

E. Kudryavtseva

Ulyanovsk State Technical University

Email: vlad-sharapov2008@yandex.ru
Rússia, Ulyanovsk

Arquivos suplementares

Arquivos suplementares
Ação
1. JATS XML

Declaração de direitos autorais © Springer Science+Business Media New York, 2016