Barring of Turbine-Driven Feed Pumps at TPPS
- Авторлар: Vasil’ev V.1, Sirotkin V.2, Erpalov A.3
-
Мекемелер:
- Chelyabinsk State University
- Nizhnevartovsk TPP
- South Ural State University (National Research University)
- Шығарылым: Том 52, № 6 (2019)
- Беттер: 720-722
- Бөлім: Article
- URL: https://journals.rcsi.science/1570-145X/article/view/246341
- DOI: https://doi.org/10.1007/s10749-019-01021-z
- ID: 246341
Дәйексөз келтіру
Аннотация
The results of analysis of the high-speed barring operation of feed pumps are presented. The absence of resonances of the drive turbine rotor over a wide speed range allows warming up feed pumps at a speed of 1650 – 2000 rpm.