Evaluating the Selection of a Booster Pump on the Suction Line of a Floating Dredge
- Авторлар: Aref’ev N.N.1
-
Мекемелер:
- Volga State University of Water Transport
- Шығарылым: Том 51, № 5 (2018)
- Беттер: 532-535
- Бөлім: Article
- URL: https://journals.rcsi.science/1570-145X/article/view/245934
- DOI: https://doi.org/10.1007/s10749-018-0868-6
- ID: 245934
Дәйексөз келтіру
Аннотация
Approaches to the prevention of cavitation in a soil pump at high soil intake rates are analyzed. It is shown that installation of an additional (booster) pump in the underwater part of a suction-type hydraulic-fill pipeline is an optimal approach. As a result of calculations it is found that axial- and diagonal-type booster pumps possess the best energy indicators.