Evaluating the Selection of a Booster Pump on the Suction Line of a Floating Dredge
- Authors: Aref’ev N.N.1
-
Affiliations:
- Volga State University of Water Transport
- Issue: Vol 51, No 5 (2018)
- Pages: 532-535
- Section: Article
- URL: https://journals.rcsi.science/1570-145X/article/view/245934
- DOI: https://doi.org/10.1007/s10749-018-0868-6
- ID: 245934
Cite item
Abstract
Approaches to the prevention of cavitation in a soil pump at high soil intake rates are analyzed. It is shown that installation of an additional (booster) pump in the underwater part of a suction-type hydraulic-fill pipeline is an optimal approach. As a result of calculations it is found that axial- and diagonal-type booster pumps possess the best energy indicators.
About the authors
N. N. Aref’ev
Volga State University of Water Transport
Author for correspondence.
Email: Arefyev1987@gmail.com
Russian Federation, Perm