Vibration-isolated foundations have been increasingly used for gas-turbine units. It is shown that vibrationisolated foundations as well as monolithic foundations require geodesic survey. The shafting of the AE64.3A gas-turbine unit is highly sensitive to the redistribution of the bearing load on the bearing part of the foundation in different operating modes and upon foundation deformation.