Reinforced Concrete Structure Strength Test in the Operating Stressed State
- Authors: Lamkin M.S.1, Turchina O.A.1
-
Affiliations:
- “B. E. Vedeneev VNIIG,” JSC
- Issue: Vol 49, No 5 (2016)
- Pages: 328-336
- Section: Article
- URL: https://journals.rcsi.science/1570-145X/article/view/244945
- DOI: https://doi.org/10.1007/s10749-016-0624-8
- ID: 244945
Cite item
Abstract
.Anew strength test procedure is proposed for operating reinforced concrete structures. The procedure is based on comparing the load-bearing capability of an existing structure to forces in it from operating loads and effects. The load-bearing capability of such structures is taken to be the limiting values of the allowable longitudinal force [N] and bending moment [M] in the given structural element, provided its strength is assured for eccentricity e0 of external force Nkon, acting in the cross-section under consideration. The design dependencies include service factors ó1 and ó2 for reinforcing steel (rebar), which describe the transmission efficiency of rebar under tension and compression, respectively. A method for determining the values of these factors is given.
About the authors
M. S. Lamkin
“B. E. Vedeneev VNIIG,” JSC
Author for correspondence.
Email: LamkinMS@vniig.ru
Russian Federation, St. Petersburg
O. A. Turchina
“B. E. Vedeneev VNIIG,” JSC
Email: LamkinMS@vniig.ru
Russian Federation, St. Petersburg
Supplementary files