Numerical simulation of a flat plate film cooling with a coolant supply into different shape indentations
- Autores: Khalatov A.A.1,2, Panchenko N.A.1,2, Severin S.D.1
-
Afiliações:
- Institute of Engineering Thermophysics
- I. Sikorsky National Technical University of Ukraine, “Kiev Polytechnic Institute”
- Edição: Volume 24, Nº 5 (2017)
- Páginas: 731-737
- Seção: Article
- URL: https://journals.rcsi.science/1531-8699/article/view/217072
- DOI: https://doi.org/10.1134/S0869864317050080
- ID: 217072
Citar
Resumo
Results of a film cooling numerical simulation over a flat plate with coolant supply into indentations of different shape are reported. The calculations were performed for the blowing-ratio changed from 0.5 to 2.0. For comparison, data for traditional film cooling scheme with one row of discrete cylindrical inclined holes were used. At small value of blowing ratio (m = 0.5), the average film-cooling efficiency is roughly identical for all indentations tested. With blowing ratio growth, the scheme with a coolant supply into the transverse trench demonstrates the best results.
Palavras-chave
Sobre autores
A. Khalatov
Institute of Engineering Thermophysics; I. Sikorsky National Technical University of Ukraine, “Kiev Polytechnic Institute”
Autor responsável pela correspondência
Email: Artem.Khalatov1942@gmail.com
Ucrânia, Kiev; Kiev
N. Panchenko
Institute of Engineering Thermophysics; I. Sikorsky National Technical University of Ukraine, “Kiev Polytechnic Institute”
Email: Artem.Khalatov1942@gmail.com
Ucrânia, Kiev; Kiev
S. Severin
Institute of Engineering Thermophysics
Email: Artem.Khalatov1942@gmail.com
Ucrânia, Kiev
Arquivos suplementares