Operating safety of a hot-shot wind tunnel with combined test gas heating in stabilization mode


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

In the present paper, we analyze emergency situations typical of short-duration wind tunnels with electric-arc or combined test-gas heating in the presence of stabilization and diaphragm-rupturing systems, which occur in the case of no discharge initiation in the settling chamber, with the capacitor battery having remained charged during the start of wind-tunnel systems. For avoiding such emergency situations, some additional changes based on using feedback elements are introduced into the wind-tunnel design: the piston of the fast-response valve is made hollow for increasing the volume of the shutoff cavity and for making the release of pressure from this cavity unnecessary; the high-pressure channel, which connects the piston and the piston rod with the settling-chamber cavity, is filled with a liquid and is closed from the side of the settling chamber with a piston; the device for controlled diaphragm breakdown is provided with an external electric circuit intended to control the diaphragm-rupturing process. Those modifications allow subsequent functioning of the wind-tunnel systems only in the presence of heat-supply-induced pressure growth in the settling chamber of the wind tunnel.

作者简介

V. Shumskii

Khristianovich Institute of Theoretical and Applied Mechanics SB RAS

编辑信件的主要联系方式.
Email: shumsky@itam.nsc.ru
俄罗斯联邦, Novosibirsk

M. Yaroslavtsev

Khristianovich Institute of Theoretical and Applied Mechanics SB RAS

Email: shumsky@itam.nsc.ru
俄罗斯联邦, Novosibirsk

补充文件

附件文件
动作
1. JATS XML

版权所有 © Pleiades Publishing, Ltd., 2017