Turbines for Water-Heating Boilers in a Thermoelectric Plant
- Autores: Solomin I.N.1, Sadykov R.A.2, Daminov A.Z.3, Futin V.A.4
-
Afiliações:
- OAO Kazenergo
- Kazan State Architecture and Construction University
- Kazan Scientific Center
- ZAO NIIturbokompressor im. Shneppa
- Edição: Volume 36, Nº 2 (2016)
- Páginas: 105-108
- Seção: Article
- URL: https://journals.rcsi.science/1068-798X/article/view/226034
- DOI: https://doi.org/10.3103/S1068798X16020222
- ID: 226034
Citar
Resumo
The turbine rotor of a system operating on the basis of the organic Rankine cycle may be analyzed by means of approximate coefficients in the polynomial describing the isobaric specific heat of Freon R245fa as a function of the temperature. Calculation of the energy balance confirms the applicability of such systems.