Contact Load in a Tight Thermomechanical Pipeline Joint
- Авторлар: Shishkin S.V.1
-
Мекемелер:
- Moscow Aviation Institute
- Шығарылым: Том 39, № 3 (2019)
- Беттер: 199-204
- Бөлім: Article
- URL: https://journals.rcsi.science/1068-798X/article/view/227661
- DOI: https://doi.org/10.3103/S1068798X19030213
- ID: 227661
Дәйексөз келтіру
Аннотация
The contact problem for pipeline connection by means of a connector with shape memory is solved. In the solution, the actual deformation of the pipe is taken into account on the basis of the thermomechanical diagram. The thermal shape recovery of the connector is modeled. The conditions in which this approach may be employed are formulated. As an example, the contact load in a joint is determined.
Негізгі сөздер
Авторлар туралы
S. Shishkin
Moscow Aviation Institute
Хат алмасуға жауапты Автор.
Email: ssshisha@yandex.ru
Ресей, Moscow, 125993
Қосымша файлдар