Stabilization of discharge pulses and peculiarities of spark load matching at electroerosive dispersion of metal and graphite granules in liquid


Дәйексөз келтіру

Толық мәтін

Ашық рұқсат Ашық рұқсат
Рұқсат жабық Рұқсат берілді
Рұқсат жабық Тек жазылушылар үшін

Аннотация

The results of experiments to reduce the instability of spark load parameters using a model of spatial electrospark dispersion for metal and graphite granules by varying the capacitance of a capacitor bank and charging voltage are presented. The conditions for spark process stabilization in a layer of metal and graphite granules are determined. The influence of the capacitance of a capacitor bank and charging voltage on the efficiency of energy distribution in the discharge circuit is shown.

Авторлар туралы

S. Petrichenko

Institute of Pulse Processes and Technologies

Хат алмасуға жауапты Автор.
Email: iipt@iipt.com.ua
Украина, pr. Oktyabrskii 43a, Nikolaev, 54018

D. Listovskii

Institute of Pulse Processes and Technologies

Email: iipt@iipt.com.ua
Украина, pr. Oktyabrskii 43a, Nikolaev, 54018

N. Kuskova

Institute of Pulse Processes and Technologies

Email: iipt@iipt.com.ua
Украина, pr. Oktyabrskii 43a, Nikolaev, 54018