System of Traction AC Power Supply with Catenary Supports Not Connected with a Railway Track


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

A system of traction ac power supply is suggested. It is revealed that grounding the supports of group grounding cables is the most promising way of providing reliable operation of existing types of distance protective systems. The probabilistic characteristics of the voltages at the catenary supports are determined taking into account the random character of parameters determining the voltage levels at the supports upon short circuits in the traction network. The mathematical expectation of the number of dangerous situations over a 100-km piece of line is calculated when using a railway track to ground supports and when using the proposed system of grounding catenary supports. It is revealed that the number of dangerous situations when grounding of the catenary supports is not done does not exceed the corresponding value over electrified piece of lines where a railway track is used to ground the supports. It was established that, when the value of resistance of the group-grounding-cable–support system is less than 7.5 Ω, the operation of traction power supply during thunderstorms is no worse than with a traction network when a railway track is used to support grounding.

作者简介

A. Kosarev

JSC Railway Research Institute

编辑信件的主要联系方式.
Email: journal-elektrotechnika@mail.ru
俄罗斯联邦, Moscow, 107996

B. Kosarev

Russian University of Transport

Email: journal-elektrotechnika@mail.ru
俄罗斯联邦, Moscow, 127994

补充文件

附件文件
动作
1. JATS XML

版权所有 © Allerton Press, Inc., 2019