A control system for thermal zones of electric resistance furnaces


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

A functional diagram of a temperature controller of electric resistance furnaces with temperature difference compensation in thermal zones by means of automatic correction of power arriving to the thermal zone is given. The additional power required for compensation of the temperature difference in thermal zones of the furnace is determined. The power depends on the temperature difference between thermal zones during heating, heating temperature, and given permissible temperature difference between thermal zones. Dependences of the relative additional power upon the temperature difference between thermal zones at heating temperatures in a range of 700–1600°C and permissible temperature differences between thermal zones 5, 15, 30, and 50°C are determined. Recommendations on the control system adjustment are given. The adaptive control system for thermal zones of electric resistance furnaces is developed.

作者简介

E. Goryachikh

Moscow Power Engineering Institute

编辑信件的主要联系方式.
Email: journal-elektrotechnika@mail.ru
俄罗斯联邦, ul. Krasnokazarmennaya 17, Moscow, 111250

补充文件

附件文件
动作
1. JATS XML

版权所有 © Allerton Press, Inc., 2016