The possibilities offered by use of solid insulation in complete switching gears and cross-linked polyethylene insulation under direct and alternating current
- Авторлар: Shul’ga R.N.1, Shul’ga A.R.2, Kovalev D.I.3, Mirzabekyan G.Z.3, Varivodov V.N.3
-
Мекемелер:
- Federal State Unitary Enterprise Lenin All-Russia Electrotechnical Institute
- OOO Eurocom
- Federal State Budgetary Educational Institution of Higher Education
- Шығарылым: Том 87, № 8 (2016)
- Беттер: 462-466
- Бөлім: Article
- URL: https://journals.rcsi.science/1068-3712/article/view/229570
- DOI: https://doi.org/10.3103/S1068371216080083
- ID: 229570
Дәйексөз келтіру
Аннотация
The prospects for use of energy cables with cross-linked polyethylene insulation (CLPE) and switching gears with solid insulation under direct and alternating current are considered. The main developments in the work of enterprises manufacturing cable products are listed, and their main characteristics are given. The advantages of cables lines with cross-linked polyethylene insulation over cable lines with paper–oil insulation are described: increased capacity, high permissible insulation temperature, smaller cable bend radius, smaller weight–size parameters, increased service life, the possibility of being laid at low temperatures, and high environmental characteristics. The global experience and main problems of application of cross-linked polyethylene insulation cables under direct high-voltage current are analyzed. The variants of performance of the insulation and structure of 6–35 kV switching gears of different producers are studied. Some functions of switching gear, typical structures, and equipment structure are listed, and the main test modes for insulation of separated section and units of the switching gears are described. Different types of solid insulation of complete switching gears (CSGs) of medium voltage are compared: with and without a grounded shield on the surface. Reduced weight–size parameters and increased electrical safety are identified as advantages of the structure with a shield. Data on perspective Russian development in the area of complete switching gears and solid insulation are presented, and the conclusions regarding their main advantages are drawn. The basic functional of the system of control and monitoring by new-generation switching gear of the is offered.
Негізгі сөздер
Авторлар туралы
R. Shul’ga
Federal State Unitary Enterprise Lenin All-Russia Electrotechnical Institute
Хат алмасуға жауапты Автор.
Email: journal-elektrotechnika@mail.ru
Ресей, Moscow
A. Shul’ga
OOO Eurocom
Email: journal-elektrotechnika@mail.ru
Ресей, Moscow
D. Kovalev
Federal State Budgetary Educational Institution of Higher Education
Email: journal-elektrotechnika@mail.ru
Ресей, Moscow
G. Mirzabekyan
Federal State Budgetary Educational Institution of Higher Education
Email: journal-elektrotechnika@mail.ru
Ресей, Moscow
V. Varivodov
Federal State Budgetary Educational Institution of Higher Education
Email: journal-elektrotechnika@mail.ru
Ресей, Moscow
Қосымша файлдар