Purification of coke-plant wastewater by means of cold plasma


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

Data regarding wastewater purification by means of cold plasma in the biochemical department at Nizhny Tagil Steel Works are analyzed in the light of new information regarding the chain oxidation of hydrocarbons and their products. In chain oxidation initiated by cold plasma, oxygen-bearing products that do not undergo chain reactions are formed. Therefore, the chemical oxygen demand of plasma-treated wastewater cannot be reduced below 300—400 mg O/L.

About the authors

N. A. Aristova

Nizhny Tagil Technological Institute

Author for correspondence.
Email: aristova-na@mail.ru
Russian Federation, Nizhny Tagil