Ignition temperature of coal 3. Multicomponent coal mixtures


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

The ignition temperature of three-component mixtures is determined. The mixtures contain coal of different metamorphic development, in various proportions. It is found that the actual ignition temperature differs from the values calculated on the basis of the sum rule; the actual ignition temperature is lower. A formula is derived for predicting the ignition temperature of three-component and multicomponent mixtures.