X-ray phase contrast imaging with optical magnification using three-block interferometer with bi-level Fresnel zone plates
- Autores: Haroutunyan L.A.1
-
Afiliações:
- Yerevan State University
- Edição: Volume 51, Nº 3 (2016)
- Páginas: 284-288
- Seção: Article
- URL: https://journals.rcsi.science/1068-3372/article/view/228101
- DOI: https://doi.org/10.3103/S1068337216030129
- ID: 228101
Citar
Resumo
The possibility of X-ray phase contrast imaging using already suggested three-block interferometer consisting of bi-level Fresnel zone plates is considered. The interferometer operates in the amplitude-division mode and does not impose strong requirements to spatial and temporal coherences of an initial radiation. The use of the Fresnel zone plates as the interferometer blocks allows one to obtain an optically magnified image of an object and to condense the radiation incident on the tested object.