Determination of the critical ionization distance and ionization zone during high-temperature field evaporation of molybdenum


Цитировать

Полный текст

Открытый доступ Открытый доступ
Доступ закрыт Доступ предоставлен
Доступ закрыт Только для подписчиков

Аннотация

Steady-state field evaporation of molybdenum at high emitter temperatures (T ∼ 2000 K) has been studied using a magnetic mass spectrometer equipped with a field ion source. Only low-charge ions (Mo+2 and Mo+) have been observed in the course of evaporation. The measured ion energies and evaporating field strengths (Fev) were used to determine the critical ionization distances (xcr) and ionization zones (Δ) for singly and doubly charged ions. The obtained xcr and Δ values show that the formation of ions takes place at a certain distance from the emitter surface.

Об авторах

N. Blashenkov

Ioffe Physical Technical Institute

Email: O.Golubev@mail.ioffe.ru
Россия, St. Petersburg, 194021

O. Golubev

Ioffe Physical Technical Institute

Автор, ответственный за переписку.
Email: O.Golubev@mail.ioffe.ru
Россия, St. Petersburg, 194021


© Pleiades Publishing, Ltd., 2016

Данный сайт использует cookie-файлы

Продолжая использовать наш сайт, вы даете согласие на обработку файлов cookie, которые обеспечивают правильную работу сайта.

О куки-файлах