Increase in the Surface Strength of Titanium Implanted with Argon Ions
- Autores: Perinskaya I.1, Rodionov I.1, Kuts L.1, Tishchenko O.1
-
Afiliações:
- Yuri Gagarin State Technical University of Saratov
- Edição: Volume 44, Nº 5 (2018)
- Páginas: 450-452
- Seção: Article
- URL: https://journals.rcsi.science/1063-7850/article/view/207671
- DOI: https://doi.org/10.1134/S1063785018050243
- ID: 207671
Citar
Resumo
We have studied the influence of argon-ion implantation at accelerating voltages within 40–130 kV in a dose range of (1–4) × 1016 ion/cm2 on the morphology, microhardness, and fatigue strength of titanium. A method of titanium surface strengthening and modification by Ar+-ion implantation is proposed, which opens new possible applications of this material in electrical devices for power engineering, chemical industry, and metallurgical equipment.