Increase in the Surface Strength of Titanium Implanted with Argon Ions
- Авторлар: Perinskaya I.1, Rodionov I.1, Kuts L.1, Tishchenko O.1
-
Мекемелер:
- Yuri Gagarin State Technical University of Saratov
- Шығарылым: Том 44, № 5 (2018)
- Беттер: 450-452
- Бөлім: Article
- URL: https://journals.rcsi.science/1063-7850/article/view/207671
- DOI: https://doi.org/10.1134/S1063785018050243
- ID: 207671
Дәйексөз келтіру
Аннотация
We have studied the influence of argon-ion implantation at accelerating voltages within 40–130 kV in a dose range of (1–4) × 1016 ion/cm2 on the morphology, microhardness, and fatigue strength of titanium. A method of titanium surface strengthening and modification by Ar+-ion implantation is proposed, which opens new possible applications of this material in electrical devices for power engineering, chemical industry, and metallurgical equipment.
Авторлар туралы
I. Perinskaya
Yuri Gagarin State Technical University of Saratov
Email: kuts70@yandex.ru
Ресей, Saratov, 410054
I. Rodionov
Yuri Gagarin State Technical University of Saratov
Email: kuts70@yandex.ru
Ресей, Saratov, 410054
L. Kuts
Yuri Gagarin State Technical University of Saratov
Хат алмасуға жауапты Автор.
Email: kuts70@yandex.ru
Ресей, Saratov, 410054
O. Tishchenko
Yuri Gagarin State Technical University of Saratov
Email: kuts70@yandex.ru
Ресей, Saratov, 410054