Broadband Filtering of an X-Ray Spectrum by Transmission through a Polycapillary Structure


Дәйексөз келтіру

Толық мәтін

Ашық рұқсат Ашық рұқсат
Рұқсат жабық Рұқсат берілді
Рұқсат жабық Тек жазылушылар үшін

Аннотация

The efficiency of broadband filtering of a polychromatic X-ray spectrum by a polycapillary structure in the region of photon energies E > 10 keV was demonstrated. A polycapillary 40.5-mm-long rod made of borosilicate glass and containing 106 parallel hexagonal capillaries was used as a filter. Filtering was performed by introducing a misalignment of 0–4 mrad between the axis of this capillary structure and the primary beam direction. The relative attenuation of spectral density observed at energies ranging from 12 to 23 keV was as high as 17 dB.