Radiation-Induced Degradation of LiF:W-Based Scintillators


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

We have studied the laws of, and reasons for, changes in the spectral and kinetic characteristics of cathodoluminescence (CL) of LiF:W scintillators irradiated by nanosecond electron pulses. It is established that the observed CL response distortions are related to the transformation of pre-irradiation defects and the accumulation of new color centers. Optimum conditions of operation of the LiF:W scintillators have been determined: preliminary exposure to a 103- to 104-Gy dose leads to a 1.5- to 2-fold increase in the CL intensity (“small-dose” effect).