Studying gas temperature variation upon aerosol injection


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

Variation of the temperature of gaseous combustion products upon pulsed injection of aqueous aerosols (water, NaCl solution, clay suspension) with droplet sizes within 40–400 μm has been experimentally studied at initial gas temperatures from 520 to 910 K. The motion of aerosol droplets in the counterflow of combustion products was visualized by panoramic optical techniques. It is established that the process of gas cooling depends on the degree of aerosol dispersion, NaCl concentration in solution, clay content in suspension, and the conditions of liquid phase injection.

About the authors

P. A. Strizhak

National Research Tomsk Polytechnic University

Author for correspondence.
Email: pavelspa@tpu.ru
Russian Federation, Tomsk, 634050

I. S. Voitkov

National Research Tomsk Polytechnic University

Email: pavelspa@tpu.ru
Russian Federation, Tomsk, 634050

G. V. Kuznetsov

National Research Tomsk Polytechnic University

Email: pavelspa@tpu.ru
Russian Federation, Tomsk, 634050


Copyright (c) 2017 Pleiades Publishing, Ltd.