Determination of Plasma Oscillations in Metals Using Total External Reflection of X-Rays
- Autores: Stozharov V.1
-
Afiliações:
- Gertsen State Pedagogical University
- Edição: Volume 64, Nº 7 (2019)
- Páginas: 977-979
- Seção: Solid State
- URL: https://journals.rcsi.science/1063-7842/article/view/203730
- DOI: https://doi.org/10.1134/S1063784219070235
- ID: 203730
Citar
Resumo
A method to determine plasma oscillations in metals with the aid of total external reflection (TER) of X-rays is proposed. It is shown that the plasmon energy, concentration of conduction electrons, and Fermi energies can be calculated using experimentally measured grazing angles of X-rays after TER. Such characteristics depend on crystallographic directions and may depend on the TER depth.
Sobre autores
V. Stozharov
Gertsen State Pedagogical University
Autor responsável pela correspondência
Email: gut1111@yandex.ru
Rússia, St. Petersburg, 191186