Determination of the lifetime of D2 and HD ions


Cite item

Full Text

Open Access Open Access
Restricted Access Access granted
Restricted Access Subscription Access

Abstract

A method for determining the lifetime of unstable ions is described. The method is based on measuring the decrease in the ion beam current onto a fixed detector with increasing path length of the ion beam from the ion source to the detector. The measurements performed for D2 and HD molecular ions have shown that their lifetimes are 3.5 ± 0.1 and 4.4 ± 0.1 μs, respectively.

About the authors

V. A. Belyaev

National Research Center “Kurchatov Institute,”

Author for correspondence.
Email: Belyaev_VA@nrcki.ru
Russian Federation, Moscow, 123182

D. A. Kozlov

National Research Center “Kurchatov Institute,”

Email: Belyaev_VA@nrcki.ru
Russian Federation, Moscow, 123182

A. A. Terent’ev

National Research Center “Kurchatov Institute,”

Email: Belyaev_VA@nrcki.ru
Russian Federation, Moscow, 123182

A. E. Trenin

National Research Center “Kurchatov Institute,”

Email: Belyaev_VA@nrcki.ru
Russian Federation, Moscow, 123182


Copyright (c) 2017 Pleiades Publishing, Ltd.

This website uses cookies

You consent to our cookies if you continue to use our website.

About Cookies