Effect of the anode material on the X-ray spectrum of micropinch discharge plasma
- Authors: Grigoryeva I.G.1, Savjolov A.S.1, Salakhutdinov G.K.1
-
Affiliations:
- National Research Nuclear University “MEPhI”
- Issue: Vol 43, No 7 (2017)
- Pages: 801-804
- Section: Applied Physics
- URL: https://journals.rcsi.science/1063-780X/article/view/186170
- DOI: https://doi.org/10.1134/S1063780X17070078
- ID: 186170
Cite item
Abstract
The effect of the elemental composition of the anode material on the parameters and X-ray spectrum of micropinch discharge plasma have been studied using a low-inductance vacuum spark device. It is shown that the plasma electron temperature Te and intensity of hard X-ray emission increase with increasing nuclear charge number Z of the anode material of the discharge system.