Measurement of Temperature and Density Profiles of the Plasma at PR-2 Facility


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

A new system of probe diagnostics at linear plasma simulator PR-2 is described, allowing us to measure the profiles of plasma temperature and density in different cross sections of the plasma column. The Langmuir probe fixed to the movable part of the two-coordinate positioning system built into the PR-2 passes the region of the discharge area during the process of measuring plasma parameters. The overall dimensions of the positioning system make it possible to mount electrical probes (magnetic probes, optical fibers, and other diagnostic equipment) covering almost the entire volume of the vacuum chamber between the magnetic mirrors of the device. We present the measurement results of local plasma parameters of the beam-plasma discharge (BPD) for different values of the input power and working gas pressure. The boundaries of appearance of discharge of three types were determined: the diffusive BPD mode, the BPD mode, and the arc mode. Dependences of the plasma concentration and temperature on the input power for different values of pressure have been also determined.

作者简介

I. Sorokin

National Research Nuclear University MEPhI (Moscow Engineering Physics Institute); Kotelnikov Institute of Radio Engineering and Electronics (Fryazino Branch)

编辑信件的主要联系方式.
Email: iasorokin@mail.ru
俄罗斯联邦, Kashirskoe sh. 31, Moscow, 115409; pl. Vvedenskogo 1, Fryazino, Moscow oblast, 141190

K. Gutorov

National Research Nuclear University MEPhI (Moscow Engineering Physics Institute)

Email: iasorokin@mail.ru
俄罗斯联邦, Kashirskoe sh. 31, Moscow, 115409

M. Bolotov

National Research Nuclear University MEPhI (Moscow Engineering Physics Institute)

Email: iasorokin@mail.ru
俄罗斯联邦, Kashirskoe sh. 31, Moscow, 115409

补充文件

附件文件
动作
1. JATS XML

版权所有 © Pleiades Publishing, Ltd., 2017