Fouling Potential Determination of a UASB Effluent Using Different Assessment Methods
- Авторлар: Salazar-Peláez M.1, Morgan-Sagastume J.M.2, Noyola A.2
-
Мекемелер:
- Universidad Autónoma Metropolitana—Unidad Azcapotzalco
- Instituto de Ingeniería
- Шығарылым: Том 40, № 3 (2018)
- Беттер: 160-166
- Бөлім: Water Treatment and Demineralization Technology
- URL: https://journals.rcsi.science/1063-455X/article/view/183807
- DOI: https://doi.org/10.3103/S1063455X18030086
- ID: 183807
Дәйексөз келтіру
Аннотация
The fouling potential of a pilot-scale UASB effluent was determined using different assessment methods (SDI and MFI tests and a mathematical analysis based on a saturation curve model). The UASB reactor was operated at HRT of 4, 8 and 12 h. Although the three methods employed were adequate as a predictive tool for UF membrane fouling, the saturation curve analysis revealed a clearer relationship between the fouling potential of the UASB effluent and the HRT applied. It was found that operating a UASB reactor under short HRT, such as 4 h, could increase membrane fouling in a post-treatment UF module.