Fouling Potential Determination of a UASB Effluent Using Different Assessment Methods


Дәйексөз келтіру

Толық мәтін

Ашық рұқсат Ашық рұқсат
Рұқсат жабық Рұқсат берілді
Рұқсат жабық Тек жазылушылар үшін

Аннотация

The fouling potential of a pilot-scale UASB effluent was determined using different assessment methods (SDI and MFI tests and a mathematical analysis based on a saturation curve model). The UASB reactor was operated at HRT of 4, 8 and 12 h. Although the three methods employed were adequate as a predictive tool for UF membrane fouling, the saturation curve analysis revealed a clearer relationship between the fouling potential of the UASB effluent and the HRT applied. It was found that operating a UASB reactor under short HRT, such as 4 h, could increase membrane fouling in a post-treatment UF module.

Авторлар туралы

M. Salazar-Peláez

Universidad Autónoma Metropolitana—Unidad Azcapotzalco

Хат алмасуға жауапты Автор.
Email: monsalazarp@gmail.com
Мексика, Mexico City

J. Morgan-Sagastume

Instituto de Ingeniería

Email: monsalazarp@gmail.com
Мексика, Mexico City

A. Noyola

Instituto de Ingeniería

Email: monsalazarp@gmail.com
Мексика, Mexico City