Control of Trace Amounts of Selenium in Drinking Waters Using the Pulse Inverse Chronopotentiometry Method
- Autores: Kopilevich V.A.1, Surovtsev I.V.2, Galimova V.M.1, Maksin V.I.1, Mank V.V.3
-
Afiliações:
- National University of Life and Environmental Sciences of Ukraine
- Intenational Academic and Research Center for Information Technologies and Systems
- National University of Food Technology
- Edição: Volume 40, Nº 6 (2018)
- Páginas: 343-347
- Seção: Analytical Water Chemistry
- URL: https://journals.rcsi.science/1063-455X/article/view/183947
- DOI: https://doi.org/10.3103/S1063455X1806005X
- ID: 183947
Citar
Resumo
A technique for measuring the selenium microconcentrations in different drinking waters using the pulse inverse chronopotentiometry method with sufficient reproducibility and accuracy based on the metrological certification criteria has been developed. It is shown that this method is expedient for monitoring the state of water sources in the environment.
Sobre autores
V. Kopilevich
National University of Life and Environmental Sciences of Ukraine
Email: galimova2201@gmail.com
Ucrânia, Kyiv
I. Surovtsev
Intenational Academic and Research Center for Information Technologies and Systems
Email: galimova2201@gmail.com
Ucrânia, Kyiv
V. Galimova
National University of Life and Environmental Sciences of Ukraine
Autor responsável pela correspondência
Email: galimova2201@gmail.com
Ucrânia, Kyiv
V. Maksin
National University of Life and Environmental Sciences of Ukraine
Email: galimova2201@gmail.com
Ucrânia, Kyiv
V. Mank
National University of Food Technology
Email: galimova2201@gmail.com
Ucrânia, Kyiv
Arquivos suplementares
