Optimization of the Radiation Parameters on Technological Installations


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

To ensure that technological installations using radionuclide sources of radiation operate at top efficiency, the effect of the irradiation system parameters on the radiation utilization factor was studied. It was found that the radiation utilization factor depends not on individual parameters of the irradiation system but rather on a certain combination of these parameters. A dimensionless criterion was determined on the basis of these investigations – a complex based on a set of parameters of installations with maximum radiation utilization factor. The radiation utilization factor was determined as a function of the irradiator–irradiated object distance. The numerical range of the criterion corresponding to the maximum radiation utilization factor is shown. Data by means of Monte Carlo calculations were selected by performing experimental studies using independent dosimetric systems.

作者简介

G. Stepanov

Research Institute of Technical Physics and Automation (NIITFA)

Email: j-atomicenergy@yandex.ru
俄罗斯联邦, Moscow

补充文件

附件文件
动作
1. JATS XML