Determination of the Most Likely Wear Zones of Pipe Bends in the Pulsed Pneumatic Conveyor at the RT-1 Plant


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

The results of an experimental investigation and numerical modeling of the most likely high-wear zones in 90° pipeline bends in the pulsed pneumatic conveyor system at the RT-1 plant of the Mayak Industrial Association are presented. The experimental studies were conducted on a model of a pulsed pneumatic conveyor system; the numerical modeling of the gas-dynamic flow in the pipeline channel was performed in a model of a two-dimensional non-stationary motion of a compressible medium. It was found on the basis of the experimental results obtained using the model and numerical modeling in the homogeneous approximation that local regions with high wear of walls in the 90° pipe bends in the pulsed pneumatic conveyor do indeed exist and their experimentally found positions agree with the calculations.

作者简介

V. Istomin

Lavrent’ev Institute of Hydrodynamics, Siberian Branch of the Russian Academy of Sciences

Email: j-atomicenergy@yandex.ru
俄罗斯联邦, Novosibirsk

D. Voronin

Lavrent’ev Institute of Hydrodynamics, Siberian Branch of the Russian Academy of Sciences

Email: j-atomicenergy@yandex.ru
俄罗斯联邦, Novosibirsk

K. Khlebus

Lavrent’ev Institute of Hydrodynamics, Siberian Branch of the Russian Academy of Sciences

Email: j-atomicenergy@yandex.ru
俄罗斯联邦, Novosibirsk

D. Patoka

Mayak Industrial Association

Email: j-atomicenergy@yandex.ru
俄罗斯联邦, Ozersk

补充文件

附件文件
动作
1. JATS XML

版权所有 © Springer Science+Business Media, LLC, part of Springer Nature, 2017