Contact-Free FA Placement Checking in VVER


如何引用文章

全文:

开放存取 开放存取
受限制的访问 ##reader.subscriptionAccessGranted##
受限制的访问 订阅存取

详细

A method of contact-free determination of FA elevations to check FA placement for purposes of better operational safety of VVER-440 and -1000 is proposed. The method includes scanning specially shaped light beams over the flat tops of the assemblies, recording the reflected signal with a TV camera, and processing the information in a computer. The measurement setup developed on the basis of this method can record a difference of 0.1 mm between the elevations of the flat tops to within 1% with admissible dispersion of 1–1.5 mm. The scanning and output of elevation information are accomplished in 10–15 min. The measurement setup to be used in the water medium of the loading zone of a nuclear reactor is implemented using radiation-resistant elements.

作者简介

S. Mankevich

Astrofizika Scientific and Production Association

Email: j-atomicenergy@yandex.ru
俄罗斯联邦, Moscow

E. Orlov

Lebedev Physical Institute, Russian Academy of Sciences (LPI RAS)

Email: j-atomicenergy@yandex.ru
俄罗斯联邦, Moscow

补充文件

附件文件
动作
1. JATS XML

版权所有 © Springer Science+Business Media, LLC, 2017